30
8008250/1F7Y/V4-0/2022-06 | SICK
O P E R A T I N G I N S T R U C T I O N S | GM901
Subject to change without notice
5
MOUNTING
5.6.3
Installing the weather protection hood for the GM901
The optionally available weather protection hood comprises a base plate (with locking
bracket) and a cover.
Fig. 14: Fastening the weather protection hood for the GM901
1
Push the base plate onto the side of the flange with tube and screw it to the duct-side
surface of the flange plate (purge air fixture) with the threaded bolts provided.
2
Position the cover on the base plate from the top; hold the cover panels slightly apart at
the side at the same time.
3
Insert the side holding catches into the counterpieces, twist and lock in.
2
nd
step
Flange plate
(purge air fixture)
Base plate
Cover
1
st
step
3
rd
step
Locking bracket