DUSTHUNTER T · Operating Instructions · 8012428 V2.2 · © SICK AG
Product Description
Su
bj
ec
t t
o c
han
ge
w
ith
ou
t n
ot
ic
e
2.3
Device features and configuration
2.3.1
Device features
The DUSTHUNTER T measuring system is available in three different device versions with
the following features:
Feature
Device version
DUSTHUNTER T50
DUSTHUNTER T100
DUSTHUNTER T200
Active measuring path 0.5...2.5/2...5/4...8 m
0.5...2.5/2...5/4...12 m
Smallest measuring
range
●
Transmission
100...50%
●
Opacity 0...50%
●
Extinction 0...0.3
●
Transmission
100...80%
●
Opacity 0...20%
●
Extinction 0...0.1
●
Transmission
100...90%
●
Opacity 0...10%
●
Extinction 0...0.045
Measurement
uncertainty
±0.8% transmission
±0.4% transmission
±0.2% transmission
Swivel error (at ±0.3°) 1% transmission
0.8% transmission
0.2% transmission
Contamination
measurement
Limit values
(transmission)
Without
On one side with pivoted
shutter in sender/receiver
unit
On both sides with
pivoted shutter
None
20% for warning
30% for malfunction
30% for warning
40% for malfunction
Self-alignment
None With
Display (on MCU)
Option
Standard
Analog output
1
3 (2x with module)
Analog input
2
Digital input
4
Relay outputs
5