Parameter
Factory setting
Hysteresis:
0 m/s to 1 m/s
0.05 m/s
8.3.9
Defining the monitoring direction for the object speed value
NOTE
The procedure for configuring the Q1 and Q2 digital outputs is identical. The configura‐
tion is illustrated on switching output Q1.
The “monitoring direction” defines the measuring object direction of movement in rela‐
tion to the device at which a switching event occurs when the object speed is exceeded.
A switching event can be triggered when the switching point for the speed is exceeded
both for an increasing as well as a decreasing distance or if movement goes in both
directions from the measuring object to the device.
Parameter
Factory setting
Positive and negative (+/-):
Both directions of movement
Positive and negative (+/-)
Positive (+):
Increasing distance of the measuring object from the device
Negative (-):
Decreasing distance of the measuring object to the device
8.3.10
Defining the switching point active state for the object speed value
NOTE
The procedure for configuring the Q1 and Q2 digital outputs is identical. The configura‐
tion is illustrated on switching output Q1.
The active state describes the relationship between the switching state (active or
inactive) and the voltage present on the digital output (high or low) (
see "Signal inputs/outputs", page 18
REFERENCE
8
8024560/1A19/2021-06-30 | SICK
O P E R A T I N G I N S T R U C T I O N S | DT1000 PROFIBUS DP and DL1000 PROFIBUS DP
75