Signal level range
Table 3: Minimal signal level for output of measured values, in distance range 0.2 m … 20 m
Fog filter
Signal level
Off
500
On
1300
Table 4: Minimum signal level for output of measured values, in distance range > 20 m
Measurement cycle time [ms]
Signal level
1
300
4
125
16
70
64
30
128
20
Rain and snow filter
The measurement certainty with precipitation can be increased using the connectible
rain and snow filter.
For more information on the rain and snow filter,
see "Configuring the rain and snow
.
Distance averaging filter
The distance averaging filter carries out a moving averaging method of the distance
value.
For more information on the distance averaging filter,
Fog filter
The measurement certainty with fog can be increased using the connectible fog filter,
"Activating/deactivating the fog filter", page 66
Kalman filter
The Kalman filter filters the distance and speed value based on a mathematical status
model.
For more information about the Kalman filter:
see "Activating/deactivating the Kalman
.
see "Activating/deactivating the Kalman filter", page 67
Speed filter
The speed filter carries out a moving averaging method of the speed value.
For more information about the speed filter:
see "Configuring the speed filter",
.
see "Configuring the speed filter", page 67
.
3.7
Interfaces
3.7.1
Signal inputs/outputs
Table 5: Overview of input/output signals
Signal
Type
Designation
1
Digital input/Digital output (switchable)
In1/Q1
2
Analog output/Digital output (switchable)
QA/Q2