5
Mounting
5.1
Overview of mounting procedure
•
Selecting and preparing the mounting location.
•
Mounting the device.
•
Align device towards object with bar code.
•
Connect device to data cable (PROFINET) and supply cable.
•
Adjust the device.
5.2
Scope of delivery
The delivery of the device includes the following components:
Table 4: Scope of delivery
Item
Component
Comments
1
Device
Depending on version
1
Printed safety note
–
5.3
Preparation for mounting
5.3.1
Mounting requirements
NOTICE
Radio interference may occur when the device is used in residential areas!
Only use the device in industrial environments (EN 61000-6-4).
■
Typical space requirement for device: See type-specific dimensional drawing and
reading field diagram.
■
Comply with technical data, such as the permitted ambient conditions for opera‐
tion of the device (e.g., temperature range, EMC interference emissions, ground
potential),
■
To prevent condensation, avoid exposing the device to rapid changes in tempera‐
ture.
■
Protect the device from direct sunlight.
■
Device must only be mounted using the pairs of threaded mounting holes provided
for this purpose.
■
Shock and vibration-free mounting.
Equipment required
■
Mounting device (bracket) with sufficient load-bearing capacity and suitable
dimensions for the device.
■
2 x M5 screws
NOTE
The screws are used for mounting the device on a mounting device supplied by the
user. Screw length is dependent on the mounting base (wall thickness of the
bracket). When using an optional SICK bracket, the screws for mounting the device
are included with delivery.
■
Tool and tape measure
5.3.2
Mounting device
The device is mounted on the bracket using two M5 blind hole threads that are in pairs
on both of the narrow sides of the device,
see "Dimensional drawings", page 55
5
MOUNTING
20
O P E R A T I N G I N S T R U C T I O N S | CLV61x Dual Port (PROFINET)
8017842/ZMG5/2017-06-12 | 8M_DR | SICK
Subject to change without notice