Device = CLV61x-xx0xxx (serial variant)
Device
1
CDB620-001
Load (e.g. PLC)
4
5
.
.
.
D
Res
C
22
GND
5
Shield
U
IN
*
V
S
GND
V
out
Result
A
GND
B
1
2
7
1
10
15
6
11
5
5
For inductive load:
6
Cable
3
Figure 49: Wiring the “Result 1” and “Result 2” digital outputs of the device in the CDB620-001 connection module.
1
Device
2
Supply voltage V
S
3
Connecting cable permanently connected with the device (male connector, D-Sub-HD, 15-pin)
4
Load (e.g. PLC)
5
Output voltage V
out
6
With inductive load: see note
7
Connection module: female connector, D-Sub-HD, 15-pin
Inductive load
NOTE
Provide an arc-suppression switch at the digital output if inductive load is present.
b
Attach a freewheeling diode directly to the load for this purpose.
Table 30: Assignment of placeholders to the digital outputs
Device
CDB620-001
Output A
Pin B
Signal C
Terminal D
Result 1
12
Res 1
20
Result 2
13
Res 2
21
Characteristic data of the digital outputs
Table 31: Characteristic data of the digital outputs “Result 1” and “Result 2”
Type
Switching
Switching behavior
PNP switching to supply voltage V
S
Default settings in the device: no function, logic: not inverted (active
high)
Properties
•
Short-circuit protected and temperature protected
•
Not electrically isolated from the supply voltage V
S
ANNEX
14
8017840/19OF/2021-10-28 | SICK
O P E R A T I N G I N S T R U C T I O N S | CLV61x
85