Operating Instructions
Chapter
10
CLV 490 Bar Code Scanner
8 008 796/0000/25-06-2002
©
SICK AG · Division Auto Ident · Germany · All rights reserved
10-39
Appendix
10.4.4
Electrical installation
Cable cross-section
The connection cables for the power supply must have a cross-section of at least
0.75 mm
2
.
See also
Chapter 5.4.2 Supply voltage, Page 5-8
Power consumption
The power consumption depends on the variant:
•
Line scanner with heater: typically 75 W and max. 90 W
•
Line scanner with oscillating mirror and heater: typically 75 W and max. 100 W
These values apply to operation without the switching outputs connected.
AMV/S 60 Connection Module
The AMV/S 60 Connection Module is not suitable to power the CLV with heater. An external
power supply pack with a higher power output should be used for this purpose.
See
Chapter 3.1.3 System requirements, Page 3-2
10.4.5
Outdoor applications
If the CLV with integrated heater is used outdoors, it should be installed in a protective hou-
sing to prevent the front window from being damaged by rain, snow, or dust. The housing
also acts as a wind protector.