O P E R AT I N G I N S T R U C T I O N S | Bulkscan®
8014829/ZV98/2018-05-07| S I C K
Subject to change without notice
4 9
ELECTRICAL INSTALLATION
Pin
Wire color
Signal
Function
3
White
OUT1
Digital output 1
1 )
4
Green
GND RS
GND serial data
5
Pink
OUT2
Digital output 2
1)
6
Yellow
Reserved
Do not use
7
Black
TD–/TxD
RS-422/RS-232
8
Gray
Reserved
Do not use
9
Red
RD+
RS-422
10
Violet
TD+
RS-422
11
Gray/pink
Reserved
Do not use
12
Red/blue
Reserved
Do not use
Tab. 9: Pin assignment of the "Data" connection
• Observe the maximum cable length (see "6.1.3 Cable lengths and wire cross-sec-
• A shielded cable is required for connecting the RS-232 or the RS-422 interface.
•
Pre-assembled connection cables with flying leads are available as accessories (see
"12.2 Accessories“ on page 96).
•
1)
Digital outputs 1 and 2: The minimum switching time from low to high is 3 ms.
Other connection cables may have different wire colors.
6.2.5
Mini-USB connection of Bullkscan
®
LMS511
The Mini-USB Interface permits the direct configuration of the Bulkscan®. The Mini-USB
connection is located on the front of the sensor under a dustprotective cap.
Fig. 31: Position of the Mini-USB connection
•
The Mini USB connection is only used for configuration of the sensor and must not
be connected permanently.
•
Configuration via USB is only possible if you have installed the USB driver during the
installation of the SOPAS configuration software. This is the case with the default
installation.
• Preassembled connection cables are available as accessories (see "12.2 Accesso-
• Always screw the dust protective cap back on when you are not using the connection.
Note
Mini-USB connection
Note