O P E R AT I N G I N S T R U C T I O N S | Bulkscan®
8014829/ZV98/2018-05-07 | S I C K
Subject to change without notice
8 2
TECHNICAL DATA
Storage temperature range
–40 °C
+70 °C (max. 24 h)
Ambient light immunity
70.000 lx
Tab. 22: Bulkscan® LMS511 data sheet
11.2
Bulkscan® LMS111 data sheet
Minimum
Typical
Maximum
Features
Infrared laser light source
895 nm
905 nm
915 nm
Laser protection class
1 (eye safe) as perEN/IEC 60825-1:
2014. Identical laser class for issue EN/IEC
60825-1:2007. Complies with 21 CFR 1040.10
with the exception of the deviations as per Laser
Notice No. 50, June 2007
Aperture angle
190°
Angular resolution
0,5°
Scan frequency
25 Hz
50 Hz
Bandwidth
No limit
Heating
yes
Operating range
Distance sensor - bulk material 0.5 m
10 m
Belt speed –30 m/s
+30 m/s
Performance
Power-up delay (temperature-dependent)
60 s
Cycle time
20 ms
40 ms
Averaging filter
0 s
3.600 s
Measurement accuracy
1)
±6 %
1)
Under reference conditions: 2 m distance to conveyor belt, 100 % object remission; reference target area
0.1024 m², 100 % object remission; averaging filter 0 s; contour smoothing setting: High
Interfaces
Serial Auxiliary/Host Interface
Protocol
Data transmission rate
RS 232 (proprietary)
57.600 Baud
Ethernet
Protocol
Data transmission rate
TCP/IP
10 Mbit/s
100 Mbit/s
Digital inputs
2
Encoder inputs
2
Digital outputs
3
Analog In-/ output:
5 diagnostic LEDs and one 7-segment display.
See accessories analog module BAM100 (see
"12.2 Accessories“ on page 96).
Electrical date
Electrical connection
5-pins M12 male connector, A-coded