COMMISSIONING
6
55
8023732/2018-09-10|SICK
Subject to change without notice
O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | AOS301-WWD
▸
In the
WatchDogOutput
parameter, define the output through which the Heartbeat
signal should be sent out.
▸
In the
WatchDogInterval
parameter, define the length of time between the on/off
states of the watchdog output.
NOTE!
A time space of 0 (ms) deactivates the heartbeat signal.
The rule file can be opened and edited. Existing rules can be changed or additional rules
supplemented. New rule files can also be created and used in the AOS301-WWD.
An example for a useful additional rule is wrong-way driver detection in a tunnel which can
be completely blocked with a traffic light. If the signal of the red traffic light is laid on the
input of the TDC-E, normal-way drivers which cross over the red light can be output as
wrong-way drivers via a digital output.
▸
NOTE!
For convenient data editing, log in as a user with the
Service
authorization
directly in the TEMS Manager.
▸
With
Info
Files
, you can open the list of previously downloaded files.
Watchdog
Editing rule file