AS30 Core
AS30 Prime
Applications hints
Repeatability
0.2 mm
30/50 µm
Higher precision
Edge guiding
yes
yes
Choosing
E
type
Width measurement
no
yes
Choosing
W
type
Position teach
yes
yes
Single point & window
mode
Enhanced functions
fix smoothing
adjustable smoothing
for smoothing rugged
edges time based
analog scale fix
scalable analog range adjustment of mea‐
surement field
Both Core and Prime:
Default Analog scale
Default direction
NOTE PLEASE TAKE CARE:
Reading direction is inverse to slide-in direction!
mA values can be adjusted in Prime version
Table 2: Connection
Pin
Color
Code
Description
1
BN = brown
+ (L+)
Supply plus
2
WH =white
Qa
Analog output 4 ... 20 mA
3
BU = blue
M
Supply minus
4
BK = black
Q (C)
Switching output or IO-Link communication
5
GY = gray
MF
Multifunction control input
GETTING STARTET
2
8025153/2019-12-10 | SICK
T E C H N I C A L I N F O R M A T I O N | AS30
5
Subject to change without notice