background image

Approach

Replacing the optical cover
1.

First, clean the safety laser scanner from the outside, so that no foreign bodies
penetrate into the open device.

2.

Unscrew the fixing screws for the optical cover.

3.

Slowly and carefully detach the optical cover from the safety laser scanner. If the
optical cover seal sticks to the safety laser scanner, carefully detach the optical
cover using a screwdriver.

4.

If necessary, remove contamination from the sealing groove and the bearing sur‐
face of the safety laser scanner. Use residue-free plastic cleaners.

5.

During the following steps, wear the gloves supplied with the new optical cover.

6.

Take the new optics cover out of the packaging and remove the residual packag‐
ing.

7.

If the seal has come loose, place the seal in the slot provided in the optics cover.

8.

Carefully push the optical cover over the mirror. Make sure that the optical cover
does not touch the mirror.

9.

Place the optics cover onto the safety laser scanner. Make sure that the optics
cover rests over the whole area.

10. Screw on the optics cover with the new fixing screws. Tightening torque: 1.0 Nm …

1.2 Nm.

11. Make sure that the optical cover is clear of dirt and damage.

Put the safety laser scanner back into operation
1.

Properly remount the safety laser scanner.

2.

Reconnect all of the electrical connections to the safety laser scanner.

3.

Carry out optics cover calibration.

4.

Start the safety function using the Safety Designer.

5.

Check the effectiveness of the protective device.

°

Generally, the protective device is checked exactly as during commissioning.

°

If during the project planning the possible tolerances of the devices have
been considered and it is ensured that the configuration, wiring, or alignment
of the safety laser scanner have not been changed, a function test is suffi‐
cient.

 

A

1

1

1

1

MOUNTING INSTRUCTIONS

8

M O U N T I N G   I N S T R U C T I O N S | nanoScan3 optics cover

8024614/2019-11-20 | SICK

Subject to change without notice

Summary of Contents for 2111696

Page 1: ...M O U N T I N G I N S T R U C T I O N S nanoScan3 optics cover de en...

Page 2: ...M O N T A G E A N L E I T U N G nanoScan3 Optikhaube de en...

Page 3: ...kratzt wird Fingerabdr cke auf der Optikhaube vermeiden Beim Tausch die Handschuhe tragen die mit der neuen Optikhaube geliefert werden b Optikhaube in trockener staub und schmutzfreier Umgebung austa...

Page 4: ...gel nicht ber hrt 9 Optikhaube auf den Sicherheits Laserscanner setzen Darauf achten dass die Optikhaube fl chig aufliegt 10 Optikhaube mit den neuen Befestigungsschrauben anschrauben Anzugsdrehmo men...

Page 5: ...A 1 1 1 1 MONTAGEANLEITUNG 8024614 2019 11 20 SICK M O N T A G E A N L E I T U N G nanoScan3 Optikhaube 5 Irrt mer und nderungen vorbehalten...

Page 6: ...M O U N T I N G I N S T R U C T I O N S nanoScan3 optics cover de en...

Page 7: ...during unpacking and mounting Prevent fingerprints on the optics cover Wear the gloves supplied with the new optics cover during replacement b Replace the optics cover in a dry environment free of dus...

Page 8: ...cover does not touch the mirror 9 Place the optics cover onto the safety laser scanner Make sure that the optics cover rests over the whole area 10 Screw on the optics cover with the new fixing screw...

Page 9: ...MOUNTING INSTRUCTIONS 8024614 2019 11 20 SICK M O U N T I N G I N S T R U C T I O N S nanoScan3 optics cover 9 Subject to change without notice...

Page 10: ...80 7425 E Mail enquiry my sick com Mexico Phone 52 472 748 9451 E Mail mexico sick com Netherlands Phone 31 0 30 229 25 44 E Mail info sick nl New Zealand Phone 64 9 415 0459 0800 222 278 tollfree E M...

Reviews: