The device behaves exactly as it does when the voltage supply is switched off and
back on again.
•
The device’s function is also re-established after serious faults if the cause has
been rectified.
•
Communication with the device is interrupted (connections for configuration,
safety function and data not relating to safety).
Factory settings
Before reconfiguring the device, you can completely reset the device to factory set‐
tings.(
Resetting the device completely
). This has the following effects.
•
The configuration is reset to the factory settings.
•
The
Maintenance
and
Authorized customer
user groups are deactivated.
•
The password of the
Administrator
user group is reset to the factory settings.
User password
In the
Roles and passwords
area, you can activate or deactivate certain user groups and
change the passwords of the various user groups.
You can also start the process to reset the password of the
Administrator
user group.
Further topics
•
•
"Resetting the password for the “Administrator” user group", page 84
7.8.1
Resetting the password for the “Administrator” user group
Overview
If you have forgotten the password of the
Administrator
user group, you can reset it with
the assistance of SICK.
Approach
1.
Request the form for resetting your password from SICK support.
2.
Connect the device to the computer via USB.
3.
Open the connected device in the device window.
4.
Click on
Identify the device
on the toolbar to ensure that the desired device is
connected.
✓
The STATE LED of the connected device flashes red and green alternately.
5.
In the main navigation pane, click on
Service
.
✓
The
Service
menu opens. Various pages are displayed in the
Navigation
area.
6.
In the navigation area, click on
User password
.
✓
The
Password management
page opens.
7.
Click on
Start process for resetting the password
.
8.
Send the information displayed on the form to SICK support.
✓
You will then receive an activation code.
9.
Enter and confirm the activation code in the field provided.
✓
The password of the
Administrator
user group is reset to factory settings (SICK‐
SAFE). The
Maintenance personnel
and
Authorized client
user groups are deactivated.
The configuration is not changed.
7.9
Starting and stopping the safety function (Safety Designer)
If the configuration of the device is error-free, you can manually start or stop the safety
function. Use the buttons on the toolbar of the device window to do this.
7
CONFIGURATION
84
O P E R A T I N G I N S T R U C T I O N S | scanGrid2 CANopen
8025990/2021-03-03 | SICK
Subject to change without notice