1.
Make sure that the environment is clean and clear of fog, moisture, and dust.
2.
Unscrew screws in the system plug and remove the system plug from the defective
safety laser scanner.
3.
Unscrew the fixing screws and remove the defective safety laser scanner.
4.
Mount the system plug on the new safety laser scanner, see “
”.
5.
Mount the new safety laser scanner, see “
Mounting the safety laser scanner
”.
6.
Check the effectiveness of the protective device. For more information, see the
operating instructions.
7.2
Completely replacing the safety laser scanner
1.
Disconnect the connecting cables the system plug.
2.
Unscrew the fixing screws and remove the defective safety laser scanner.
3.
Mount the new safety laser scanner, see “
Mounting the safety laser scanner
”.
4.
Reconnect the connecting cables to the system plug.
5.
Configure the safety laser scanner.
6.
Perform commissioning again, taking particular care to conduct all of the thorough
checks described. For more information, see the operating instructions.
8
Replacing the system plug
NOTICE
Enclosure rating IP65 only applies if the safety laser scanner is closed and the system
plug is mounted.
NOTICE
If the system plug is mounted with excessive force, the contacts can break or bend.
b
Plug in the system plug carefully.
b
Do not force it.
Replacing the system plug:
Tool required:
•
TX10 Torx wrench
Approach
1.
Make sure that the environment is clean and clear of fog, moisture, and dust.
2.
Disconnect the connecting cables the system plug.
3.
If necessary: move the safety laser scanner to a clean location.
MOUNTING INSTRUCTIONS
12
M O U N T I N G I N S T R U C T I O N S | microScan3 Core I/O AIDA
8021255/1AM9/2021-02-19 | SICK
Subject to change without notice
Summary of Contents for 1083076
Page 1: ...M O U N T I N G I N S T R U C T I O N S microScan3 Core I O AIDA Safety laser scanner de en ...
Page 2: ...M O N T A G E A N L E I T U N G microScan3 Core I O AIDA Sicherheits Laserscanner de en ...
Page 8: ...M O U N T I N G I N S T R U C T I O N S microScan3 Core I O AIDA Safety laser scanner de en ...