4.
Unscrew screws in the defective system plug and remove the system plug from the
safety laser scanner.
5.
Make sure that the seal
1
is seated correctly.
6.
Carefully place the new system plug onto the safety laser scanner at the back
2
.
7.
Carefully fold the system plug onto the safety laser scanner
3
.
8.
Screw in the system plug using the captive screws. Tightening torque: 1.6 Nm …
1.9 Nm.
9.
Reconnect the connecting cables to the system plug.
10. Configure the safety laser scanner.
11. Perform commissioning again, taking particular care to conduct all of the thorough
checks described. For more information, see the operating instructions.