4
Mounting the safety laser scanner directly
Direct mounting:
The safety laser scanner has 4 M5 threaded holes on the back. If you are able to drill
through the mounting surface from the rear, you can mount the safety laser scanner
directly using these threaded holes.
b
Use either the rear
1
or the side
2
M5 threaded holes for direct mounting.
b
Use all four rear or all four side M5 threaded holes for direct mounting, so that the
values given in the data sheet for vibration and shock resistance are achieved.
b
Maximum depth of thread engagement: 7.5 mm.
b
Tightening torque: 4.5 Nm to 5.0 Nm.
5
Connection overview
MICSX-ABHZZZZZ1 (part number: 2087958)
6
Pin assignment
6.1
Connecting cable with M12 plug connector
Male connector, M12, 5-pin, A-coded.
2
1
4
3
5
Pin
Designation Function
1
+24 V DC
Supply voltage (+24 V DC)
2
OSSD 1.B
OSSD pair 1, OSSD B
3
0 V DC
Supply voltage (0 V DC)
4
OSSD 1.A
OSSD pair 1, OSSD A
5
FE
Functional earth/shield
Thread
FE
Functional earth/shield
6.2
Alternative FE connection
Figure 1: Alternative FE connection
MOUNTING INSTRUCTIONS
10
M O U N T I N G I N S T R U C T I O N S | microScan3 Core I/O AIDA
8021255/1AM9/2021-02-19 | SICK