11.2   

Door Settings 

Relay Output Delay Time

 

To set door relay strike time 

 

Master code

 

#

 

  4      0

99      #

 

0-99 is to set the door relay time 0-99 seconds 

Door Open Detection   

Door  Open  Too  Long  (DOTL)  warning

.  When  used  with  an  optional  magnetic  contact  or  built-in 

magnetic contact of the lock, if the door is opened normally, but not closed after 1 minute, the inside 

buzzer  will beep  automatically  to remind  people to close the door and continue  for 1 minute before 

switching off automatically. 

Door Forced Open warning. 

When used with an optional magnetic contact or built-in magnetic contact 

of the lock, if the door is forced open, or if the door is opened after 20 seconds ,the inside buzzer and 

alarm  output  will  both  operate.  The  Alarm  Output  time  is  adjustable  between  0-3  minutes  with  the 

default being 1 minute.

 

To  disable  door  open  detection.  (Factory 

default) 

  6      0      # 

To enable door open detection 

  6      1      # 

Alarm output time

 

To set the alarm output time (0-3 minutes) 

Factory default is 1 minute   

  5      0

3      #

 

Keypad Lockout & Alarm Output options

If there are 10 invalid cards or 10 incorrect PIN numbers 

in a 10 minute period either the keypad will lockout for 10 minutes or both the alarm and the inside 

buzzer will operate for 10 minutes, depending on the option selected below.

 

Normal  status:  No  keypad  lockout  or 

alarm (factory default) 

  7      0      # (Factory default setting) 

Keypad Lockout 

  7      1      # 

Alarm and inside buzzer operate     

  7      2      # 

To remove the alarm

 

To reset the Door Forced Open warning 

Read valid card

 or 

Master Code # 

To reset the Door Open Too Long warning  Close the door 

or 

  Read valid card

 or 

Master Code # 

 

12.The unit operating as a Wiegand Output Reader 

In  this  mode  the  unit  supports  a  Wiegand  26  bit  output  so  the  Wiegand  data  lines  can  be 

connected to any controller which supports a Wiegand 26 bit input.   

 

 

 

Summary of Contents for Standalone Keypad Access Control

Page 1: ...Standalone Keypad Access Control User Manual...

Page 2: ...programming mode Note that to undertake the following programming the master user must be logged in To change the master code 0 New code New code The master code can be 6 to 8 digits To add a PIN user...

Page 3: ...t short circuit protection Wiegand output and a backlit keypad These features make the unit an ideal choice for door access not only for small shops and domestic households but also for commercial and...

Page 4: ...ds Adjustable Alarm Time 0 3 minutes Wiegand Interface Wiegand 26 bit Wiring Connections Electric Lock Exit Button External Alarm 6 Installation l Remove the back cover from the keypad using the suppl...

Page 5: ...d 12V 12V DC Regulated Power Input Black GND 12V DC Regulated Power Input Blue NO Relay normally on end Connect positive electric lock Purple COM Relay Public end connect GND Orange NC Relay Closed en...

Page 6: ...Di Alarm Bright Alarm 11 Detailed Programming Guide 11 1 User Settings To enter the programming mode Master code 999999 is the default factory master code To exit from the programming mode Note that...

Page 7: ...alternative way to enter cards using User ID Allocation In this method a User ID is allocated to a card Only one user ID can be allocated to a single card 1 ID number Read card User can be added conti...

Page 8: ...PIN mode Method 1 Note that this is done outside programming mode so the user can undertake this themselves Read Card Old PIN New PIN New PIN To change a PIN in card and PIN mode Method 2 Note that th...

Page 9: ...being 1 minute To disable door open detection Factory default 6 0 To enable door open detection 6 1 Alarm output time To set the alarm output time 0 3 minutes Factory default is 1 minute 5 0 3 Keypad...

Page 10: ...10...

Reviews: