background image

 

The  ID  number  is  any  number  between  1  &  2000.  The 

PIN  is  any  four  digits  between  0000  &  9999  with  the 

exception of 1234 which is reserved. Users can be added 

continuously  without  exiting  programming  mode  as 

follows: 

1    User ID no 1 #    PIN # User ID no 2 #    PIN # 

To delete a 

PIN

 user 

2    User ID number    #     

Users  can  be  deleted  continuously  without  exiting 

programming mode 

To change the 

PIN

 of a PIN user   

(This  step  must  be  done  out  of 

programming mode) 

  *    ID number #    Old PIN #    New PIN #    New PIN # 

To add a 

card

 user (Method 1) 

This  is  the  fastest  way  to  enter  cards, 

user ID number auto generation. 

1    Read card    # 

Cards  can  be  added  continuously  without  exiting 

programming mode 

To add a 

card

 user (Method 2) 

This is the alternative way to enter cards 

using User ID Allocation. In this method a 

User  ID  is  allocated  to  a  card.  Only  one 

user ID can be allocated to a single card. 

1      ID number    #    Read card    # 

User  can  be  added  continuously  without  exiting 

programming mode 

To add a 

card

 user (Method 3) 

Card  number  is  the  last  8  digits  printed 

on  the  back  of  the  card,user  ID  number 

auto generation 

1    Card number    # 

  User  can  be  added  continuously  without  exiting 

programming mode 

To add a 

card

 user (Method 4) 

In this method a User ID is allocated to a 

card  number.  Only  one  user  ID  can  be 

allocated to the card number 

 

  1      ID number. #    Card number. #   

User  can  be  added  continuously  without  exiting 

programming mode

 

To delete a 

card

 user by card. Note users 

can  be  deleted  continuously  without 

exiting programming mode 

2      Read Card        #   

To  delete  a 

card 

user  by  user  ID.  This 

option can be used when a user has lost 

their card 

2      User ID      #   

 

Summary of Contents for Standalone Keypad Access Control

Page 1: ...Standalone Keypad Access Control User Manual...

Page 2: ...programming mode Note that to undertake the following programming the master user must be logged in To change the master code 0 New code New code The master code can be 6 to 8 digits To add a PIN user...

Page 3: ...t short circuit protection Wiegand output and a backlit keypad These features make the unit an ideal choice for door access not only for small shops and domestic households but also for commercial and...

Page 4: ...ds Adjustable Alarm Time 0 3 minutes Wiegand Interface Wiegand 26 bit Wiring Connections Electric Lock Exit Button External Alarm 6 Installation l Remove the back cover from the keypad using the suppl...

Page 5: ...d 12V 12V DC Regulated Power Input Black GND 12V DC Regulated Power Input Blue NO Relay normally on end Connect positive electric lock Purple COM Relay Public end connect GND Orange NC Relay Closed en...

Page 6: ...Di Alarm Bright Alarm 11 Detailed Programming Guide 11 1 User Settings To enter the programming mode Master code 999999 is the default factory master code To exit from the programming mode Note that...

Page 7: ...alternative way to enter cards using User ID Allocation In this method a User ID is allocated to a card Only one user ID can be allocated to a single card 1 ID number Read card User can be added conti...

Page 8: ...PIN mode Method 1 Note that this is done outside programming mode so the user can undertake this themselves Read Card Old PIN New PIN New PIN To change a PIN in card and PIN mode Method 2 Note that th...

Page 9: ...being 1 minute To disable door open detection Factory default 6 0 To enable door open detection 6 1 Alarm output time To set the alarm output time 0 3 minutes Factory default is 1 minute 5 0 3 Keypad...

Page 10: ...10...

Reviews: