background image

 

To unlock the door for a card user 

Present the card   

3.  Description   

The  unit  is  single  door  multifunction  standalone  access  controller 

or

  a  Wiegand  output 

keypad  or  card  reader.  It  is  suitable  for  mounting  either  indoor  or  outdoor  in  harsh 

environments.  It  is  housed  in  a  strong,  sturdy  and  vandal  proof  Zinc Alloy  electroplated 

case  which  is  available  in  either  a  bright  silver  or  matt  silver  finish.  The  electronics  are 

fully potted so the unit is waterproof and conforms to IP68. This unit supports up to 2000 

users in either a Card, 4 digit PIN, or a Card + PIN option. The inbuilt card reader supports 

125KHZ  EM  cards,13.56MHz  Mifare  cards.  The  unit  has  many  extra  features  including 

lock output current short circuit protection, Wiegand output , and a backlit keypad. These 

features  make  the  unit  an  ideal  choice  for  door  access  not  only  for  small  shops  and 

domestic households but also for commercial and industrial applications such as factories, 

warehouses, laboratories, banks and prisons. 

4.  Features 

l

 

Waterproof, conforms to IP68   

l

 

Strong Zinc Alloy Electroplated anti-vandal case 

l

 

Full programming from the keypad 

l

 

2000 uses, supports Card, PIN, Card + PIN   

l

 

Can be used as a stand alone keypad 

l

 

Backlight keys 

l

 

Wiegand 26 output for connection to a controller             

l

 

Adjustable Door Output time, Alarm time, Door Open time   

l

 

Very low power consumption (30mA)   

l

 

Fast operating speed, <20ms with 2000 users 

l

 

Lock output current short circuit protection 

l

 

Easy to install and program 

l

 

Built in light dependent resistor (LDR) for anti tamper 

l

 

Built in buzzer 

l

 

Red, Yellow and Green LEDS display the working status 

Summary of Contents for Standalone Keypad Access Control

Page 1: ...Standalone Keypad Access Control User Manual...

Page 2: ...programming mode Note that to undertake the following programming the master user must be logged in To change the master code 0 New code New code The master code can be 6 to 8 digits To add a PIN user...

Page 3: ...t short circuit protection Wiegand output and a backlit keypad These features make the unit an ideal choice for door access not only for small shops and domestic households but also for commercial and...

Page 4: ...ds Adjustable Alarm Time 0 3 minutes Wiegand Interface Wiegand 26 bit Wiring Connections Electric Lock Exit Button External Alarm 6 Installation l Remove the back cover from the keypad using the suppl...

Page 5: ...d 12V 12V DC Regulated Power Input Black GND 12V DC Regulated Power Input Blue NO Relay normally on end Connect positive electric lock Purple COM Relay Public end connect GND Orange NC Relay Closed en...

Page 6: ...Di Alarm Bright Alarm 11 Detailed Programming Guide 11 1 User Settings To enter the programming mode Master code 999999 is the default factory master code To exit from the programming mode Note that...

Page 7: ...alternative way to enter cards using User ID Allocation In this method a User ID is allocated to a card Only one user ID can be allocated to a single card 1 ID number Read card User can be added conti...

Page 8: ...PIN mode Method 1 Note that this is done outside programming mode so the user can undertake this themselves Read Card Old PIN New PIN New PIN To change a PIN in card and PIN mode Method 2 Note that th...

Page 9: ...being 1 minute To disable door open detection Factory default 6 0 To enable door open detection 6 1 Alarm output time To set the alarm output time 0 3 minutes Factory default is 1 minute 5 0 3 Keypad...

Page 10: ...10...