SI Zen Roll Owner'S Manual Download Page 6

6

Bottom opening width

Top opening width

Middle opening width

Total unit width

= Middle opening width - 1/4''

Total 

unit 

height 

Total 

opening 

height

2 38 "

Weight bar and Gasket

Open roll

 7" MIN 

10" MIN 

3 78 "

4 12 "

SPECIFYING YOUR SHADE DIMENSIONS

Use this formula for specifying shades were the roll and cable guide can be seen from the inside of 
the installation opening.

 

Width - 

Measure the total width at the top, middle, and bottom of your opening. Take the smallest 

measurement of the three and deduct a total of 1/4". This will give you the TOTAL UNIT WIDTH of 
your shade. 

Drop - 

Measure the total height of your opening. That will be your TOTAL UNIT DROP for your shade. 

We do manufacture the tracks or guides for your system 5" longer than your TOTAL UNIT HEIGHT so 
you can have a little adjustment on site. 

The measurements written on the order form 

will be the measurements produced. No 

deductions are taken on submitted order form.

MINIMUM OPENING WIDTH - 1/4''   =   TOTAL UNIT WIDTH   =  W
TOTAL HEIGHT OF OPENING            =   TOTAL UNIT HEIGHT  =  H

Between Columns Ceiling Mount

Summary of Contents for Zen Roll

Page 1: ...Zen Roll Owner s Manual INSTALLERS PLEASE LEAVE THIS MANUAL WITH THE OWNER with Cable Guides...

Page 2: ...ll transportation expenses This warranty is in lieu of all other warranties express or implied including warranties as to fitness for use and merchant ability Any implied warranties of fitness for use...

Page 3: ...ng 5 Specifying Your Shade Dimensions 6 7 Parts in the Box 8 Install Brackets 9 Install Material Roll 10 11 Cable Mount Options 12 Installing Cable Guides 13 16 Power Motorized only 17 Set Limits Moto...

Page 4: ...raction of the shade system DO NOT lower shade during high wind conditions gusts over 20 mph Doing so will result in damage that will need to be repaired by a qualified technician If the shade system...

Page 5: ...mount and shade boxes will be mounted to Before removing the screen from the packaging check for damage and to make sure all parts are included Do not use any sharp blades when opening the screen pac...

Page 6: ...ttom of your opening Take the smallest measurement of the three and deduct a total of 1 4 This will give you the TOTAL UNIT WIDTH of your shade Drop Measure the total height of your opening That will...

Page 7: ...s plumb parellel If not order extra width to keep cable guide out of view from the inside LARGEST OPENING WIDTH 3 1 2 TOTAL UNIT WIDTH W TOTAL HEIGHT OF OPENING 10 TOTAL UNIT HEIGHT H Width Measure th...

Page 8: ...bly my my Shades Or Motor Bracket Idler Bracket Cables 2 Cable Tensioners 2 Floor Mounts 2 Wall Mounts 2 Cable Mounting Options Mounting Bracket Options Telis Remote 1 Foldable Crank Handle For Manual...

Page 9: ...ion from outside to outside Also make sure the motor bracket is on the correct side as specified on the order The brackets must be mounted on a level line as well as plumb The brackets can be mounted...

Page 10: ...aterial roll idler shaft Use 2 people to lift up the material roll and guide the motor into the star bracket Make sure the power and control cables exit the desired direction Installation requires two...

Page 11: ...11 Lift the idler end with bushing already installed up into the idler housing Then secure with the screw removed in step 1 INSTALLING MATERIAL ROLL 3...

Page 12: ...12 1 77 47 1 60 1 12 18 thru 36 x 82 2 20 19 27 70 1 60 1 00 70 1 70 27 2 Floor Mount CABLE MOUNT OPTIONS Wall Mount...

Page 13: ...13 Run the larger crimped end of the Cable Guide up through the hole in the weight bar Then slide over the guide cable bracket in the case or attached to the motor end plate INSTALLING CABLE GUIDES 1...

Page 14: ...all mount brackets using appropriate fasteners Make sure that they are secured at a location such that the cables will be plumb in both directions and parallel to each other Note that the wall mount b...

Page 15: ...rs onto the mounts making sure that they are threaded out as much as possible so that there will be thread available to tension the cables Cut the cables such that they are the same length so that the...

Page 16: ...in the tensioners with the locknut Make sure that the cables are mounted level and plumb in all directions As a final check make sure that the left and right cables are the same distance apart from t...

Page 17: ...ccordance with the appropriate electrical codes and regulations by a licensed electrical professional Do not connect power with the circuit breaker on Before connecting power to multiple units be awar...

Page 18: ...st by pressing or Step 7 Set user mode Press and hold the programming button on the back of the transmitter until the shade jogs The shade is now in User Mode In User Mode the shade will operate with...

Page 19: ...mitter to add or delete Step 3 Select the transmitter single channel or the channel 1 5 of a multi channel transmitter to be added or deleted Step 4 Press and hold the programming button of that trans...

Page 20: ...conds and then press UP briefly again The sceen will jog slowly and is now deactivated If the jog is short you ve reached the default setting To deactivate press up again To Increase Sensitivity Press...

Page 21: ...screen surface Debris or particles adhering to screen due to static cling Check back of screen as well as front of screen for dust or debris Wipe the back of the screen with a clean damp cloth Also l...

Page 22: ...Screen Innovations 9715 B Burnet Rd Suite 400 Austin TX 78758 512 832 6939 www screeninnovations com v 1 2 15 October 2019...

Reviews: