![SI Zen Roll Owner'S Manual Download Page 16](http://html1.mh-extra.com/html/si/zen-roll/zen-roll_owners-manual_1263280016.webp)
16
TENSIONING THE GUIDE CABLES -
4
Insert the cable into the tensioner all the way to the bottom of the tensioner and secure with the set
screws. Then tension the cable by tightening the nut for wall mount brackets or the tensioner itself
for floor mount. Finally lock in the tensioners with the locknut. Make sure that the cables are mounted
level and plumb in all directions. As a final check make sure that the left and right cables are the same
distance apart from top to bottom within 1/4’’.
NOTE: Cables may lose tension over time. In that case simply
tighten the tensioners and lock in with the lock nut.
PL
UMB
PL
UMB
Insert cable and bottom out
into the tensioners
4A
Secure with
set screws
4B
Turn bottom nut to
tension cable
4C