8.3 Installation
Procedure
1. RF coaxial cable installation must comply with local or National
Electrical Codes and must be with nominal 50-Ohm impedance. Pull
and route the RF coaxial cables as per the site installation plan.
2. Fix the supplied connectors to the RF coaxial cable and
verify the
following:
•
The center conductor to outer shield of RF coaxial cable
indicates an “Open Circuit” condition.
•
Check for any short circuit between center conductor and
outer shield.
•
Short one end of the conductor between center conductor
and outer shield by piece of wire temporarily and check the
other end of conductor for any break in the RF cable.
3. Record the
R-20-930 unit
serial number for use when contacting
SHYAM customer service for support.
4. Mount the unit on the intended wall surface using the appropriate
screws
.
5. Install the indoor coverage antenna according to the antenna
manufacturer’s instructions. Connect the RF coaxial cable between the
indoor antenna and the “MS” port on the unit.
7. Install the donor antenna (Outdoor Yagi antenna) according to the
antenna manufacturer’s instructions. Connect the RF coaxial cable
between the donor antenna port and the “BTS ” port on the unit.
Connections as indicated below may be carried out:
•
RF cable from Donor antenna to “BTS” port.
•
RF cable from Server antenna to “Mobile” port.
•
AC mains through power supply adopter.
8.4 Commissioning
1. Plug the AC/DC power adaptor to the Repeater and switch ON the unit.
2. Once the repeater is ON, the LEDs will not glow under normal
condition.