Function of the LED
* Green Light:
The green LED is inside of the controller. If
the wiring from the panel
correct, the
green light (LED) will be on.
* Red Light:
The red LED is on the front side of the
controller. The red light is on:
a. If the float switch (remote control) is on a
high position and the reservoir is full
(bridged).
b. If the water table inside the well is lowered
to the level of the LOW sensor and the dry
running protection of the pump is in function.
Battery Use
If the LCB Pump Controller is used in conjunction with batteries
and charge regulators, there must be a 10 A fuse on the cable to the
battery.
* IMPORTANT: Check for the correct cable ("+" /"-")
connection!!
Installation
1)
If installing on a post, you may use the included Bracket and
screws.
2)
Connect the PV-panel cable, while covering the solar
modules against sunshine (radiation). Correct connection
will be indicated by the GREEN LED.
3)
Attach the HI/LOW/GRD sensors at the desired depth on
the pressure pipe of the solar pump and the safety wire.
4)
Connect the solar pump cable. Tighten carefully!
5)
Test the function by switching the manual switch (inside
enclosure, upper right corner) to the "ON" position some
seconds.
6)
Connect the sensor cable while using the black isolation
tube. Insert all 3 wires through the isolation cable and then
insert through the cable connector. Tighten carefully!!
Follow the sequence of the sensor settings,
HIGH-sensor to the HIGH-cable connector, etc.
IMPORTANT:
If the HI/LOW/GRD terminals are not used with level
sensors they must be bridged. The RED LED is in
function when there is a low water level
.
Do not ground hot wire (+, -) but unit housing
7)
If required, connect the float switch with the terminals.
"Bridged", Stops the pump
"RED LED".
Summary of Contents for LCB-G
Page 5: ...August1999...