background image

 

LCB - G Specification

 

 
* Maximum input voltage 

 

45 VDC (Open Circuit) under 
all conditions 

 
* Start up voltage with 

 

12.5 V    

 

 

 

 

 

one module 17,5 mpp  

 

 
* Start up voltage with 

 

25.0 V    

 

 

 

 

 

two modules 17,5 mpp in 

series 
 
* Maximum output voltage   

29 volts  

 
* Maximum power consumption 

150 Watts 

   of the PV-pump-system 
 
* Maximum output current 

 

7 Amps 

 
* Power consumption  

 

25 mA 

 
* Fuse   

 

 

 

10 Amps (optional inserted on 
the battery cable) 

 
* Ambiente temperature 

 

14°F - 113°F ( -10°C..+45°C ) 

 
* Short-circuit protection 
 

 

 

Features

 

 
1)  Current boosting for matching the load requirements of the 
pump motor. 
2)  Adjustable voltage of the starting point of the pump. 
3)  Weatherproof cast aluminum enclosure. 
4)  4x water tight cable inlets 
5)  Voltage limiting for pump protection 
6)  Remote float switch circuit. 
7)  Low water cut off circuit with adjustable set points. 
8)  ON / OFF Pump switch (inside enclosure) 
9)  Power-in indicator (green LED, inside enclosure)  
     ("ON", if the wiring from the panel is correct) 
10)  Pump-out indicator (red LED, outside) 
11)  One year limited warranty 
 

Power Matching of the Controller

 

 
For use on panel direct systems, the LCB Pump Controller is set to 
hold  the voltage constant  around the maximum power point of the 
panels, and match the electric requirements of the pump motor. The 
purpose  for  the  matching  of  the  electric  conditions  of  the  power 
source  (MPP)  with  the  consumer  (load)  is  to  maximize  the  daily 
output of the solar pumping system. 

 