Certification

Model C1-PS 30s A

UL Listed to UL 6500, 2nd Edition, cUL Listed to 
CAN/CSA E60065-00. Authorized under the 
Verification provision of FCC Part 15 as a Class B 
Digital Device. This Class B Digital apparatus 
complies with Canadian ICES-003.

Model C1- PS 30s E, C1-PS 30s UK

Conforms to European Community Directives,
eligible to bear CE Mark; TUV GS-Certified to EN 
60065, 6th Edition; Meets EMC Requirements of 
EN 55103 (Parts 1 & 2), Environments E1 & E2.  
Meets Australian EMC Requirements, eligible to 
bear C-Tick Mark.

Model C1- PS 30s J

TUV (PSE) Certified to J 60065

Information to User

Changes or modifications not expressly approved by Shure Manufacturing GmbH could void your
authority to operate this equipment.

This equipment has been tested and found to comply with the limits of a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can radia-
te radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.

English

17

8

Summary of Contents for ConferenceONEs

Page 1: ...User Guide Model User Guide 2002 Shure Europe GmbH 27A8779 Printed in Germany TM...

Page 2: ...safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 PROTECT the power cord from being walked on or pinched particularly at plugs...

Page 3: ...m with standard Neutrik Minicon connectors Daisy chain connections from one console to the next Integrated loudspeakers in the consoles Additional headphone output with adjustable volume in each conso...

Page 4: ...between monitoring the audio input and output The LEDs illuminate to indicate which source you are currently monitoring Power LED Illuminates when the unit is switched on with the power switch 1 4 2...

Page 5: ...etween microphone and line level and adds phantom power for condenser microphones Daisy chain sockets Minicon sockets for connecting the consoles via bus cables Audio input Electronically balanced inp...

Page 6: ...ain sockets Minicon socket for connection and through connection of the console bus The sockets are interchangeable either one may be used as an input or an output Headphone socket 1 8 stereo headphon...

Page 7: ...mode for adjusting the volume of the conference system 1 2 3 6 7 8 Loudspeaker Transmits the sum signal from the conference system The loudspeaker automatically switches off when the local microphone...

Page 8: ...arious components The following general rules must always be observed when setting up the system Always switch off the power supply unit before connecting or disconnecting consoles or bus cables Do no...

Page 9: ...from each console to the next The sockets on the rear of the power supply unit can be used in parallel to the front socket However the total number of consoles must not exceed 30 English C1 Cs Chairm...

Page 10: ...to a connected condenser microphone Press the ON OFF button in the input section to activate the audio input on the rear of the unit The LED above this button illuminates green when the input is acti...

Page 11: ...nes 4 2 2 Using the Menu With Limit set to 1 a timer displays how long the currently active microphone has been on In normal operating mode when the status page is displayed the volume of the system c...

Page 12: ...the value and then press SELECT to return to the status page Setup Limit 4 Chime ON OFF The following diagram shows the entire menu tree Volume 12 Limit 1 12 42 Volume 12 Limit 4 Volume 12 Setup Limit...

Page 13: ...s allow for optimum level matching to a hybrid codec that may require higher or lower than nominal speech signal levels to properly operate To maintain the same input and output level the switches sho...

Page 14: ...state English 6 13 6 2 Operating Instructions To set the volume of the system 1 Press or button to change the volume 2 Press SELECT to return to the Status Page To limit the number of active micropho...

Page 15: ...heir sockets Feedback whistling 7 Troubleshooting Problem Remedy Move the consoles farther apart Reduce the system volume on the chairman console Delegate microphone cannot be activated lightring on m...

Page 16: ...ce 8 Ohm Socket 1 4 stereo jack socket Connections Maximum number of consoles per console bus branch Minicon 15 Maximum total number of consoles 30 Maximum length of a console bus branch 40 m English...

Page 17: ...Distortion factor 0 3 Audio input to audio output Frequency range 50 Hz 18 kHz Distortion factor 0 3 Mechanical data Dimensions H x W x D Power supply unit C1 PS 30s 88 1 x 482 6 x 237 mm Chairman con...

Page 18: ...B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates use...

Page 19: ...4 6 5 Minicon Bus Cable Pin Signal Cable Color Code 1 Audio 1 black 2 Control 2 blue 3 24 V gray 4 GND brown 5 GND purple 6 GND pink gray 7 GND red 8 24 V pink 9 Control 3 yellow 10 Control 1 green 1...

Page 20: ...sales shure de Unit 301 3 Floor Citicorp Centre 18 Whitfield Road Causeway Bay Hong Kong Phone 852 2893 4290 Fax 852 2893 4055 E mail sales shure com hk rd Shure Incorporated 5800 W Touhy Avenue Nile...