background image

English

CONTENT

User Guide

Conference

ONE

™s Standard Discussion System 

1 Introduction

2

1.1

Features

2

1.2

Components

2

2 Description

3

2.1

Power Supply Unit C1-PS 30s

3/4

2.2

Delegate Console C1-Ds

5

2.3

Chairman Console C1-Cs

6/7

3 Setting Up

7

3.1

General Notes

7

3.2

Possible Configurations

8

4 System Settings

9

4.1

Power Supply Unit

9

4.2

Chairman Console

10

4.2.1

Status Page

10

4.2.2

Using the Menu

10/11

4.3

Test Mode

11

4.4

Language Selection

12

5 AEC / Telco Audio Interface (Optional)

12

5.1

Interface Levels

12

5.2

Balanced / Unbalanced Connections

12

5.3

External Interface Device Settings

12

6 System Operation

13

6.1

General

13

6.2

Operating Instructions

13

7 Troubleshooting

14

8 Technical Data

15/16

9 Appendix - Connector Pin Assignments

17

1

1. READ these instructions.
2. KEEP these instructions.
3. HEED all warnings.
4. FOLLOW all instructions.
5. DO NOT use this apparatus near water.
6. CLEAN ONLY with dry cloth.
7. DO NOT block any ventilation openings. Install in accordance with
the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers,
stoves, or other apparatus (including amplifiers) that produce heat.
9. DO NOT defeat the safety purpose of the polarized or groundingtype
plug. A polarized plug has two blades with one wider than the other. A
grounding type plug has two blades and a third grounding prong. The
wider blade or the third prong are provided for your safety. If the
provided plug does not fit into your outlet, consult an electrician for
replacement of the obsolete outlet.
10. PROTECT the power cord from being walked on or pinched,
particularly at plugs, convenience receptacles, and the point where they
exit from the apparatus.

11. ONLY USE attachments/accessories specified by the manufacturer.
12. USE only with a cart, stand, tripod, bracket, or table specified by the

manufacturer, or sold with the apparatus. When a cart is used, use

caution when moving the cart/apparatus combination to avoid

injury from tip-over.

13. UNPLUG this apparatus during lightning storms or when

unused for long periods of time.

14. REFER all servicing to qualified service personnel. Servicing

is required when the apparatus has been damaged in any way, such

as power-supply cord or plug is damaged, liquid has been spilled or
objects have fallen into the apparatus, the apparatus has been exposed
to rain or moisture, does not operate normally, or has been dropped.
15. DO NOT expose the apparatus to dripping and splashing. DO NOT
put objects filled with liquids, such as vases, on the apparatus.

WARNING: 

Voltages in this equipment are hazardous to life. No user-serviceable parts inside. Refer all servicing to qualified service personnel. The

safety certifications do not apply when the operating voltage is changed from the factory setting.

IMPORTANT SAFETY INSTRUCTIONS !

This symbol indicates that there are important operating
and maintenance instructions in the literature
accompanying this unit.

This symbol indicates that dangerous voltage
constituting a risk of electric shock is present within
this unit.

Summary of Contents for ConferenceONEs

Page 1: ...User Guide Model User Guide 2002 Shure Europe GmbH 27A8779 Printed in Germany TM...

Page 2: ...safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 PROTECT the power cord from being walked on or pinched particularly at plugs...

Page 3: ...m with standard Neutrik Minicon connectors Daisy chain connections from one console to the next Integrated loudspeakers in the consoles Additional headphone output with adjustable volume in each conso...

Page 4: ...between monitoring the audio input and output The LEDs illuminate to indicate which source you are currently monitoring Power LED Illuminates when the unit is switched on with the power switch 1 4 2...

Page 5: ...etween microphone and line level and adds phantom power for condenser microphones Daisy chain sockets Minicon sockets for connecting the consoles via bus cables Audio input Electronically balanced inp...

Page 6: ...ain sockets Minicon socket for connection and through connection of the console bus The sockets are interchangeable either one may be used as an input or an output Headphone socket 1 8 stereo headphon...

Page 7: ...mode for adjusting the volume of the conference system 1 2 3 6 7 8 Loudspeaker Transmits the sum signal from the conference system The loudspeaker automatically switches off when the local microphone...

Page 8: ...arious components The following general rules must always be observed when setting up the system Always switch off the power supply unit before connecting or disconnecting consoles or bus cables Do no...

Page 9: ...from each console to the next The sockets on the rear of the power supply unit can be used in parallel to the front socket However the total number of consoles must not exceed 30 English C1 Cs Chairm...

Page 10: ...to a connected condenser microphone Press the ON OFF button in the input section to activate the audio input on the rear of the unit The LED above this button illuminates green when the input is acti...

Page 11: ...nes 4 2 2 Using the Menu With Limit set to 1 a timer displays how long the currently active microphone has been on In normal operating mode when the status page is displayed the volume of the system c...

Page 12: ...the value and then press SELECT to return to the status page Setup Limit 4 Chime ON OFF The following diagram shows the entire menu tree Volume 12 Limit 1 12 42 Volume 12 Limit 4 Volume 12 Setup Limit...

Page 13: ...s allow for optimum level matching to a hybrid codec that may require higher or lower than nominal speech signal levels to properly operate To maintain the same input and output level the switches sho...

Page 14: ...state English 6 13 6 2 Operating Instructions To set the volume of the system 1 Press or button to change the volume 2 Press SELECT to return to the Status Page To limit the number of active micropho...

Page 15: ...heir sockets Feedback whistling 7 Troubleshooting Problem Remedy Move the consoles farther apart Reduce the system volume on the chairman console Delegate microphone cannot be activated lightring on m...

Page 16: ...ce 8 Ohm Socket 1 4 stereo jack socket Connections Maximum number of consoles per console bus branch Minicon 15 Maximum total number of consoles 30 Maximum length of a console bus branch 40 m English...

Page 17: ...Distortion factor 0 3 Audio input to audio output Frequency range 50 Hz 18 kHz Distortion factor 0 3 Mechanical data Dimensions H x W x D Power supply unit C1 PS 30s 88 1 x 482 6 x 237 mm Chairman con...

Page 18: ...B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates use...

Page 19: ...4 6 5 Minicon Bus Cable Pin Signal Cable Color Code 1 Audio 1 black 2 Control 2 blue 3 24 V gray 4 GND brown 5 GND purple 6 GND pink gray 7 GND red 8 24 V pink 9 Control 3 yellow 10 Control 1 green 1...

Page 20: ...sales shure de Unit 301 3 Floor Citicorp Centre 18 Whitfield Road Causeway Bay Hong Kong Phone 852 2893 4290 Fax 852 2893 4055 E mail sales shure com hk rd Shure Incorporated 5800 W Touhy Avenue Nile...

Reviews: