4
11
Use the
Limit
menu item to specify the maximum
number of microphones that can be activated
simultaneously in addition to the chairman console. If
the
Limit
is set to 1, the timer is displayed. Press
or
buttons to change the value and then press
SELECT to return to the status page.
Use the
Chime
menu item to specify whether or not a
chime will sound when the PRIORITY button is pressed
on the chairman console. Press
or
button to
change the value and then press SELECT to return to
the status page.
S e t u p
L i m i t 4
C h i m e
O N
O F F
The following diagram shows the entire menu tree.
V o l u m e 1 2
L i m i t 1 1 2 : 4 2
V o l u m e 1 2
L i m i t 4
V o l u m e 1 2
S e t u p
L i m i t C h i m e E x i t
C h i m e
O N
O F F
S e t u p
L i m i t 4
4.3 Test Mode
Activate test mode by pressing and holding both of
the
and
buttons for approximately three seconds.
The installed software version appears in the display and
the lightrings on all delegate consoles illuminate in order
to permit simple detection of any cable breakages or
defective consoles.
Press the SELECT button to return to normal operating
mode.
C o n f e r e n c e O n e
S H U R E V e r . 1 . 0 s
English