9
Maintenance
The Showtec Titan Strobe requires almost no maintenance. However, you should keep the unit clean.
Otherwise, the fixture’s light-output will be significantly reduced.
Disconnect the mains power supply, and
then wipe the cover with a damp cloth. Do not immerse in liquid. Wipe glass clean with glass cleaner and a
soft cloth. Do not use alcohol or solvents.
The glass will require regular cleaning, as smoke-fluid tends to build up residues, reducing the light-output
quickly.
Keep connections clean. Disconnect electric power, and then wipe the DMX and audio connections with a
damp cloth. Make sure connections are thoroughly dry before linking equipment or supplying electric
power.
The following points have to be considered during the inspection:
1.
All screws used for installing the device or parts of the device have to be tightly connected and must
not be corroded.
2.
There may not be any deformations on housings, fixations and installation spots.
3.
The electric power supply cables must not show any damages or material fatigue.
Changing the Lamp
1.
Disconnect mains power supply.
2.
Follow directions for installing a new lamp, page 6.
Replacing a Fuse
Power surges, short-circuit or inappropriate electrical power supply may cause a fuse to burn out. If the fuse
burns out, the product will not function whatsoever. If this happens,
follow the directions below to do so.
1.
Unplug the unit from electric power source.
2.
Insert a screwdriver into the slot in the fuse cover. Turn the screwdriver to the left, at the same time gently
push a bit (Turn and Push). The fuse will come out.
3.
Remove the used fuse. If brown or unclear, it is burned out.
4.
Insert the replacement fuse into the holder where the old fuse was. Reinsert the fuse cover. Be sure to
use a fuse of the same type and specification. See the product specification label for details.
Troubleshooting
No Light
This troubleshooting guide is meant to help solve simple problems. If a problem occurs, carry out the steps
below in sequence until a solution is found. Once the unit operates properly, do not carry out following steps.
If the light effect does not operate properly, refer servicing to a technician.
Response: Suspect three potential problem areas: the power supply, the lamp, the fuse.
1.
Power supply. Check that the unit is plugged into an appropriate power supply.
2.
The lamp. Replace the old lamp with a new one with the same specifications. See page 6 for replacing
lamps.
3.
The fuse. See page 9 for the fuse.
No Response to DMX
Response: Suspect the DMX cable or connectors, a controller malfunction, a light effect DMX card
malfunction.
1.
Check the DMX cable: Unplug the unit; change the DMX cable; then reconnect to electrical power. Try
your DMX control again.
2.
Determine whether the controller or light effect is at fault. Does the controller operate properly with other
DMX products ? If not, take the controller in for repair. If so, take the DMX cable and the light effect to a
qualified technician.