Avoid flames and do not put close to flammable liquids or gases. 

 

Always replace the lamp, when it is damaged or deformed due to the heat. 

 

Always keep case closed while operating. 

 

Always allow free air space of at least 50 cm around the unit for ventilation. 

 

Always disconnect power from the mains, when device is not used, before cleaning or when 
replacing lamp! Only handle the power-cord by the plug. Never pull out the plug by tugging the 
power-cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power-cord is never crimped or damaged. Check the device and the power-
cord from time to time. 

 

Make sure that the core diameter of extension cords and power cords is sufficient for the required 
power consumption of the device. 

 

If device is dropped or struck, disconnect main power supply immediately. Have a qualified engineer 
inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 
switch it on immediately. The arising condensation water might damage your device. Leave the 
device switched off until it has reached room temperature. 

 

If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely 
(preferably in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. Lighteffect must be installed out of the reach of children. Never leave the unit 
running unattended. 

 

For replacement use lamps of same type and rating only. 

 

Allow time to cool down, before replacing lamp.  

 

Keep away from direct insulation. 

 

This device is only allowed for an installation via the mounting bracket. 

 

The user is responsible for correct positioning and operating of the Titan Strobe. The manufacturer will 
not accept liability for damages caused by the misuse or incorrect installation of this device. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 
conductor to earth. 

 

The relative humidity must not exceed 50 % with an ambient temperature of 45° C. 

 

During the initial start-up some smoke or smell may arise. This is a normal process and does not 
necessarily mean that the device is defective. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 

 
 
 
 
 

OPERATING DETERMINATIONS 

 

This device is not designed for permanent operation. Consistent operation breaks will ensure that the device 
will serve you for a long time without defects. 
 
The minimum distance between light-output and the illuminated surface must be more than 0.8 meter. 
 
The maximum ambient temperature 

t

a

 must never be exceeded. 

 
If this device is operated in any other way, than the one described in this manual, the product may suffer 
damages and the

 

warranty becomes void.  

Any other operation may lead to dangers like short-circuit, burns, electric shock, lamp explosion, crash etc. 

 

You endanger your own safety and the safety of others! 

CAUTION ! EYEDAMAGES !. 

Avoid looking directly into the light source. 

(meant especially for epileptics) !

 

 

Summary of Contents for Titan Strobe 3000

Page 1: ...Titan Strobe 3000 ORDERCODE 40251 ...

Page 2: ...on Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied For more information iwant showtec info You can get some of the best quality best priced products on the market from Showtec So next time turn to Showtec for more great lightin...

Page 3: ...y instructions Operating Determinations Rigging Description Features and Overview Backside Installation Installing the Lamp Set Up and Operation Self test Mode DMX Dip Switch Setting Maintenance Changing the Lamp Replacing the Fuse Troubleshooting No Light No Response to DMX Product Specifications ...

Page 4: ...nite the lamp if the objective lens or any housing cover is open as discharge lamps may expose and emit a high ultraviolet radiation which may cause burns Never look directly into the light source Never leave any cables lying around Never modify bend mechanically strain put pressure on pull or heat up the power cord Never strain the cable insert or the female part in the device There must always b...

Page 5: ... the reach of children Never leave the unit running unattended For replacement use lamps of same type and rating only Allow time to cool down before replacing lamp Keep away from direct insulation This device is only allowed for an installation via the mounting bracket The user is responsible for correct positioning and operating of the Titan Strobe The manufacturer will not accept liability for d...

Page 6: ...stallation must always be secured with a safety attachment e g an appropriate safety net or safety cable When rigging derigging or servicing the strobe always make sure that the area below the installation place is blocked and staying in the area is forbidden Improper installation can cause serious damage to people and property Connection with the mains Connect the device to the mains with the pow...

Page 7: ...ls Strobe effect with adjustable speed 1 25 flashes sec Lamp PX 1500W Fuse 20A 250V Overview Fig 1 Backside Fig 2 1 Power Indicator Indicates when power is on 2 DMX Indicator Indicates when DMX signal is available 3 Dip Switches 4 DMX signal connector OUT XLR female socket to connect another unit 5 DMX signal connector IN XLR male socket to receive DMX signals 6 Fuse T20A 250V 6 3x32mm ...

Page 8: ...he left hand gently pull the lamp out the spring while pushing the spring back with the right hand 3 Remove the lamp Read lamp instructions Do not touch the lamp bulb glass Oil on hands shortens the lamp life If you touch the bulb glass wipe off the glass with a clean lint free towel and rubbing alcohol Hold the lamp with one hand and Insert the lamp into the spring Put the glass cover back Set Up...

Page 9: ...witch 9 to ON it performs a MANUAL self test Dip switch 1 2 3 are assigned to control Flash Speed Dip switch 4 5 6 are assigned to control Flash Dimmer Dip switch 7 and 8 are assigned to control the Flash duration Auto Self test Mode Set dip switch 9 to OFF the strobe performs an AUTO self test Dip switch 1 8 are assigned to adjust the duration level ...

Page 10: ...annel 3 Flash Duration DMX products must have their own address to receive DMX signals Addresses on the Showtec Titan Strobe are set by flipping the appropriate DMX dip switches You need to know that DMX address settings are the sum of the dip switch values Example Titan strobe Address Value DMX Dip Switches ON Unit 1 17 1 5 Switch Value 1 1 5 16 Total sum 17 Once address values are determined add...

Page 11: ... Unplug the unit from electric power source 2 Insert a screwdriver into the slot in the fuse cover Turn the screwdriver to the left at the same time gently push a bit Turn and Push The fuse will come out 3 Remove the used fuse If brown or unclear it is burned out 4 Insert the replacement fuse into the holder where the old fuse was Reinsert the fuse cover Be sure to use a fuse of the same type and ...

Page 12: ... pin XLR female Strobe effect with variable speed 1 flash 25 flashes sec DMX control via standard DMX controller Lamp PX 1500W ordercode 82690 Minimum distance Minimum distance from flammable surfaces 0 5m Minimum distance to lighted object 0 8m Versions for other lamps may be produced Please check the specification label on your product Design and product specifications are subject to change with...

Page 13: ...2007 Showtec ...