Model: Showtec Spider LED 

 

New and exciting lighting effect which creates a flowering effect 

 

Pre-programmed shows are perfectly synchronized to the beat of the music by its built in music control 

 

Wide Beam angle 

 

Vivid colors 

 

DMX Control 

 

Exciting Flower effect 

 

5 lenses ensure razor sharp beams 

 

Light Source: 320 LEDs (120 red, 120 green, 80 blue) 

 

Power Input: 100-230V 50/60Hz 

 

Long LED lifetime 

 

Peak Power 63 Watt 

 

Continuous Power 45 Watt 

 

Control: Auto Run, Sound, Master/Slave, DMX 

 

Sound-active program selectable by DMX 

 

Music-controlled via built-in microphone 

 

DMX Channels: 10 

 

Powerconnector: IEC In and IEC Out 

 

Data Connector: In/Out (XLR 3 Pin) 

 

Strobe: 0-20Hz 

 

Plug & Play 

 

Stand-alone 

 

Fuse 2A / 250V 

 

Dimensions: 285 x 240 x 300 mm (LxWxH) 

 

Weight: 2,94 kg 

 

Optional Accessories: IEC cables, 90465, 90446, 90466, 43098 

 
 
 
 

Minimum distance: 

Minimum distance from flammable surfaces: 0.5m 
Minimum distance to lighted object: 0.8m 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
Design and product specifications are subject to change without prior notice.  

 

 

 

Website: 

www.Showtec.info

 

Email: 

[email protected]

 

Summary of Contents for Spider LED

Page 1: ...Spider LED ORDERCODE 43107 Highlite International B V Vestastraat 2 6468 EX Kerkrade The Netherlands Phone 31 45 5667700...

Page 2: ...Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you o...

Page 3: ...Control Modes 7 One Spider LED Auto Run Programs 7 One Spider LED Sound control 8 Multiple Spider LEDs Master Slave control 8 Multiple Spider LEDs DMX Control 9 Fixture Linking 10 Data Cabling 10 Dips...

Page 4: ...s will be achieved under normal operational conditions If improving on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may include clim...

Page 5: ...that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the power cord from time to time If the external c...

Page 6: ...tallation yourself Always let the installation be carried out by an authorized dealer Procedure If the Spider LED is lowered from the ceiling or high joists professional trussing systems have to be us...

Page 7: ...description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our ann...

Page 8: ...Peak Power 63 Watt Continuous Power 45 Watt Control Auto Run Sound Master Slave DMX Sound active program selectable by DMX Music controlled via built in microphone DMX Channels 10 Powerconnector IEC...

Page 9: ...to Run Programs 1 Fasten the effect light onto firm trussing Leave at least 0 5 meter on all sides for air circulation 2 Plug the end of the electric mains power cord into a proper electric power supp...

Page 10: ...rol 1 Fasten the effect light onto firm trussing Leave at least 0 5 meter on all sides for air circulation 2 Plug the end of the electric mains power cord into a proper electric power supply socket 3...

Page 11: ...g with the first unit Do not supply power before the whole system is set up and connected properly Multiple Spider LEDs DMX Set Up Fig 3 Note Link all cables before connecting electric power Controlli...

Page 12: ...ter may result in deterioration of the digital DMX signal Maximum recommended DMX data link distance 100 meters Maximum recommended number of Spider LEDs on a DMX data link 30 fixtures Data Cabling To...

Page 13: ...Explanation Since each unit has 10 channels each address advances 10 values See Address Value above Once address values are determined add DMX dip switch values to obtain the appropriate address DMX D...

Page 14: ...12 DMX Quick Reference Chart...

Page 15: ...ogram 11 88 95 Built in Program 12 96 103 Built in Program 13 104 111 Built in Program 14 112 119 Built in Program 15 120 127 Built in Program 16 128 135 Built in Program 17 136 143 Built in Program 1...

Page 16: ...upplying electric power The operator has to make sure that safety relating and machine technical installations are to be inspected by an expert after every four years in the course of an acceptance te...

Page 17: ...4 If all of the above appears to be O K plug the unit in again 5 If you are unable to determine the cause of the problem do not open the Spider LED as this may damage the unit and the warranty will be...

Page 18: ...ect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture o...

Page 19: ...63 Watt Continuous Power 45 Watt Control Auto Run Sound Master Slave DMX Sound active program selectable by DMX Music controlled via built in microphone DMX Channels 10 Powerconnector IEC In and IEC...

Page 20: ......

Reviews: