9
Multiple Spider LEDs (DMX Control)
1.
Fasten the effect light onto firm trussing. Leave at least 0,5 meter on all sides for air circulation.
2.
Always use a safety cable (ordercode 70140 / 70141).
3.
Use a 3-p XLR cable to connect the Spider LED and other devices.
4.
Link the units as shown in (figure 3), Connect a DMX signal cable from the first unit's DMX "out" socket
to the second unit's "in" socket. Repeat this process to link the second, third, and fourth units.
5.
Supply electric power: Plug electric mains power cords into each unit's IEC socket, then plug the
other end of the mains power cord into proper electric power supply sockets, starting with the first
unit. Do not supply power before the whole system is set up and connected properly.
Multiple Spider LEDs DMX Set Up
Fig. 3
Note : Link all cables before connecting electric power
Controlling:
After having addressed all Spider LED fixtures, you may now start operating these via your lighting
controller.
Note:
After switching on, the Spider LED will automatically detect whether DMX 512 data is received or
not. If there is no data received, the problem may be:
•
The XLR cable from the controller is not connected with the input of the Spider LED.
•
The controller is switched off or defective, the cable or connector is detective, or the signal wires are
swapped in the input connector.
Note:
It’s necessary to insert a XLR termination plug (with 120 Ohm) in the last fixture in order to ensure
proper transmission on the DMX data link.