11
Problem
Probable cause(s)
Remedy
One or more
fixtures are
completely dead.
No power to the fixture
· Check that power is switched on
and cables are plugged in.
Fuse blown.
· Return the Sky Rose to your dealer.
Fixtures reset
correctly, but all
respond
erratically or not
at all to the
controller.
The controller is not connected.
· Connect controller.
Fixtures reset
correctly, but
some respond
erratically or not
at all to the
controller.
Poor data quality
· Check data quality. If much lower
than 100 percent, the problem may
be a bad data link connection, poor
quality or broken cables, missing
termination plug, or a defective
fixture disturbing the link.
Bad data link connection
· Inspect connections and cables.
Correct poor connections. Repair or
replace damaged cables.
One of the fixtures is defective and
disturbs data transmission on the
link.
· Bypass one fixture at a time until
normal operation is regained: unplug
both connectors and connect them
directly together.
· Have the defective fixture serviced
by a qualified technician.
No light
The power supply settings do not
match local AC voltage and
frequency.
· Disconnect fixture. Check settings
(page 8) and correct if necessary.
Lamp missing or blown
· Disconnect fixture and replace lamp.
Lamp cuts out
intermittently.
Fixture is too hot.
· Allow fixture to cool.
· Clean fan.
· Make sure air vents at control panel
and front lens are not blocked.
· Turn up the air conditioning.
The power supply settings do not
match local AC voltage and
frequency.
· Disconnect fixture. Check settings
(page 8) and correct if necessary.