21
Pixelbar 16 Q6
Product code: 41308
Select KlingNet IP in the Set IP Mode menu. See 6.6.8. Set IP Mode on page 30. The Kling-Net-based
software will automatically configure the IP address of the device.
Select KlingNet Protocol in the Set Net Protocol menu. See 6.6.11. Set Net Protocol on page 31.
Map the device following the instructions of the Kling-Net-based software.
Universe Numbering
If you want to connect more than 5 devices on one data link and use them in 101-channel mode, you
will need to address them on different universes.
Set the DMX starting address of the first 5 devices. Follow the instructions in 5.3.5. DMX Addressing on
page 18.
Set the universe number of the 6
th
device to 001 and the DMX starting address to 001.
Continue addressing the devices, each time increasing the universe number, after the limit of 512
channels for one universe has been reached.
There are 512 channels (1–512) in one universe. 16 consecutive universes (0–15) make up one sub-net. 16
sub-nets (0–15) make up one net. There are in total 128 nets (0–127).
Note:
●
In Art-Net, universes are called Port Address and number from 0 to 32767. There are 32768 unique
numbers.
●
In sACN, universes number from 1 to 63999.
15-bit
Port Address
Net
(0–127)
Sub-net
(0–15)
Universe
(0–15)
0
0
0
0
1
0
0
1
2
0
0
2
...
...
...
...
15
0
0
15
16
0
1
0
17
0
1
1
...
...
...
...
31
0
1
15
32
0
2
0
33
0
2
1
...
...
...
...
255
0
15
15
256
1
0
0
257
1
0
1
...
...
...
...
32766
127
15
14
32767
127
15
15
Make sure that you do not have any overlapping channels in order to control each Pixelbar 16 Q6
correctly. If two or more devices are addressed similarly, they will work similarly.
Note:
If you are using an Art-Net controller that supports Art-Net I or Art-Net II, the Art-Net net
must be set to 0. The net number is available in Art-Net 3 and higher versions of the Art-Net
protocol.