SHOWTEC LED City Painter 45 User Manual Download Page 4

 

WARNING 

 
 
 
 
 

 

FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY  

BEFORE YOUR INITIAL START-UP! 

 

SAFETY INSTRUCTIONS 

Every person involved with the installation, operation and maintenance of this device has to: 

-

 

be qualified 

-

 

follow the instructions of this manual 

 
 
 
 
 
 

Before your initial start-up, please make sure that there is no damage caused by transportation. Should 
there be any, consult your dealer and do not use the device. 

 

To maintain perfect condition and to ensure a safe operation, it is absolutely necessary for the user to 
follow the safety instructions and warning notes written in this manual. 

 

This manual must be kept with the fixture for future consultation. In the event of the fixture being sold or 
passed to another user, always make certain that the booklet is with the unit, to enable the new owner to 
be informed on its operation and relative care. 

 

Please consider that damages caused by manual modifications to the device are not subject to 
warranty. 

 

This device contains no user-serviceable parts. Refer servicing to qualified technicians only. 

 

IMPORTANT:

 

The manufacturer will not accept liability for any resulting damages caused by the non-
observance of this manual or any unauthorized modification to the device. 

 

 

Never let the power-cord come into contact with other cables! Handle the power-cord and all 
connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Never run the device without lamp! 

 

Never ignite the lamp if the objective-lens or any housing-cover is open, as discharge lamps may 
expose and emit a high ultraviolet radiation, which may cause burns. 

 

Never lift the fixture by holding it at the projector-head, as the mechanics may be damaged. 
Always hold the fixture at the transport handles. 

 

Never look directly into the light source. 

 

Never leave any cables lying around. 

 

Never unscrew the screws of the rotating gobo, as the ball bearing will otherwise be opened. 

 

Never use the device during thunderstorms, unplug the device immediately. 

 

Never leave various parts of the packaging (plastic bags, polystyrene foam, nails, etc.) within 
children’s reach, as they are potential sources of danger. 

 

Do not insert objects into air vents. 

 

Do not connect this device to a dimmerpack. 

 

Do not switch the device on and off in short intervals, as this would reduce the lamp’s life. 

 

If the lamp has been turned OFF, let the lamp cool down for 15 minutes, before turning the lamp 
ON again. 

 

Do not touch the device’s housing bare-handed during its operation (housing becomes very hot).  

CAUTION! 

Keep this device away from rain and moisture! 

Unplug mains lead before opening the housing!

 

CAUTION! Be careful with your operations. 

With a dangerous voltage you can suffer 

a dangerous electric shock when touching the wires!

 

 

Summary of Contents for LED City Painter 45

Page 1: ...LED City Painter 45 ORDERCODE 40906...

Page 2: ...y on Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep y...

Page 3: ...g Description Features and Overview Backside Installation Installing the Lamp Set Up and Operation One City Painter Multiple City Painters Control Panel Control Mode DMX Addressing Multiple City Paint...

Page 4: ...power cord and all connections with the mains with particular caution Never remove warning or informative labels from the unit Never use anything to cover the ground contact Never run the device witho...

Page 5: ...is obviously damaged it has to be replaced So that its functions are not impaired due to cracks or deep scratches If device is dropped or struck disconnect mains power supply immediately Have a qualif...

Page 6: ...ne described in this manual the product may suffer damages and the warranty becomes void Any other operation may lead to dangers like short circuit burns electric shock lamp explosion crash etc You en...

Page 7: ...g an appropriate safety net or safety cable When rigging derigging or servicing the LED City Painter always make sure that the area below the installation place is blocked and staying in the area is f...

Page 8: ...Screw provided 2 Turn the bracket 45 to uncover the top fixing screws of the front panel 3 Remove the first two screws with a screwdriver not supplied 4 Turn the head s horizontal positioning bracket...

Page 9: ...programs with each max 10 scenes DMX control via standard DMX controller Create Programs and scenes to start at a certain time and date 7 DMX control channels required IP 65 Protection degree 24 Red L...

Page 10: ...DMX signal connector IN 5 DMX signal connector OUT Installation Installing the LED Lights The Showtec LED City Painter 45 uses LED lights LED lights do not have to be replaced Damages caused by non ob...

Page 11: ...le to connect the City Painters and other devices The pins 1 Earth 2 Signal 3 Signal 3 Link the units as shown in figure 3 Connect a DMX signal cable from the first unit s DMX out socket to the second...

Page 12: ...e any overlapping channels in order to control each LED City Painter correctly If two or more LED City Painters are addressed similarly they will work similarly For address settings please refer to th...

Page 13: ...9 197 59 407 30 204 60 414 Colour temperature The CTC channel allows to adjust Palco s colour temperature It acts in a range around the white balance or Full Color according to requirements It s there...

Page 14: ...Green saturation adjustment 0 100 Channel 5 Blue 0 255 Linear Green saturation adjustment 0 100 Channel 6 CTC Color Correction 0 255 From Cold 2000 K to Warm 2000 k compared to balanced white or not C...

Page 15: ...13...

Page 16: ...NTER once you have the intensity you want You now return to the previous menu 7 If you want to exit the entire Colour Balance Menu press and hold down the ENTER button for six seconds 1 Use the UP DOW...

Page 17: ...ur setting and exit the BOOST menu Note Using BOOST means the overall lifetime of the LEDs goes from 100 000 to 50 000 hours No Function No Function No Function No Function 5 Input Signal The Signal m...

Page 18: ...tant to set the LED City Painter s internal clock for later use in Stand alone mode 1 Use the UP DOWN buttons to scroll through the display until it shows Time 2 Press and hold down the ENTER button f...

Page 19: ...ll show Red Press the ENTER button and the fixture will test the RED LEDs Press and hold down the ENTER button for six seconds to return to the previous menu 4 Use the UP DOWN buttons to select RED GR...

Page 20: ...to choose between ON or OFF 4 Press ENTER to store your setting and exit the Master menu 15 Configuring Slaves When multiple City Painters are connected in stand alone Mode one device has to be the m...

Page 21: ...UP Button to scroll through the menu until the display shows Dimmer 0 255 Use the UP DOWN buttons to change the value from 0 255 Press the ENTER button to store your setting and return to the previous...

Page 22: ...ntil it shows Sched1 2 Press the ENTER button and the display will show event 1 36 Use the UP DOWN buttons to change the value from 1 36 Press the ENTER button to store your setting and return to the...

Page 23: ...tribution Testing Circumstances Installation position horizontal Max Luminous intensity 4569 49 cd Luminous Flux 1640 01 lm Luminous Efficiency 17 50 lm w Source voltage 220 V Current Source 0 777 A P...

Page 24: ...Replacing a Fuse Power surges short circuit or inappropriate electrical power supply may cause a fuse to burn out If the fuse burns out the product will not function whatsoever If this happens follow...

Page 25: ...Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixtu...

Page 26: ...g DIP Switches DMX Channels 7 Signal input 3 pin XLR male Signal output 3 pin XLR female IP Protection Grade IP65 Electro mechanical effects DMX control via standard DMX controller Color effect 3 Colo...

Page 27: ......