Multiple City Painters & DMX Addresses 

 
 

LED City Painter No 

DMX Address 

 

LED City Painter No 

DMX Address 

001 

 

31 

211 

008 

 

32 

218 

015 

 

33 

225 

022 

 

34 

232 

029 

 

35 

239 

036 

 

36 

246 

043 

 

37 

253 

050 

 

38 

260 

057 

 

39 

267 

10 

064 

 

40 

274 

11 

071 

 

41 

281 

12 

078 

 

42 

288 

13 

085 

 

43 

295 

14 

092 

 

44 

302 

15 

99 

 

45 

309 

16 

106 

 

46 

316 

17 

113 

 

47 

323 

18 

120 

 

48 

330 

19 

127 

 

49 

337 

20 

134 

 

50 

344 

21 

141 

 

51 

351 

22 

148 

 

52 

358 

23 

155 

 

53 

365 

24 

162 

 

54 

372 

25 

169 

 

55 

379 

26 

176 

 

56 

386 

27 

183 

 

57 

393 

28 

190 

 

58 

400 

29 

197 

 

59 

407 

30 

204 

 

60 

414 

 
 

Colour temperature 

The CTC channel allows to adjust Palco’s colour temperature. It acts in a range around the white 
balance or Full-Color, according to requirements. It’s therefore possible to cool or heat in a linear manner 
absolutely any type of previously chosen white by more or less 2000 K°. 
 

Shutter/Strobe 

The Shutter/Strobe channel allows an endless number of shutter effects to be achieved. As well as the 
adjustable frequency strobe effect (from 1 Hz to 20 Hz), it’s possible to create Random-Strobe effects at 
three different speeds. 
Low – Medium - High). Palco is also fitted with a Pulse Open and Close effect for each of the three 
different speeds (Low – Medium – High) 

 
 
 
 
 
 

Summary of Contents for LED City Painter 45

Page 1: ...LED City Painter 45 ORDERCODE 40906...

Page 2: ...y on Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep y...

Page 3: ...g Description Features and Overview Backside Installation Installing the Lamp Set Up and Operation One City Painter Multiple City Painters Control Panel Control Mode DMX Addressing Multiple City Paint...

Page 4: ...power cord and all connections with the mains with particular caution Never remove warning or informative labels from the unit Never use anything to cover the ground contact Never run the device witho...

Page 5: ...is obviously damaged it has to be replaced So that its functions are not impaired due to cracks or deep scratches If device is dropped or struck disconnect mains power supply immediately Have a qualif...

Page 6: ...ne described in this manual the product may suffer damages and the warranty becomes void Any other operation may lead to dangers like short circuit burns electric shock lamp explosion crash etc You en...

Page 7: ...g an appropriate safety net or safety cable When rigging derigging or servicing the LED City Painter always make sure that the area below the installation place is blocked and staying in the area is f...

Page 8: ...Screw provided 2 Turn the bracket 45 to uncover the top fixing screws of the front panel 3 Remove the first two screws with a screwdriver not supplied 4 Turn the head s horizontal positioning bracket...

Page 9: ...programs with each max 10 scenes DMX control via standard DMX controller Create Programs and scenes to start at a certain time and date 7 DMX control channels required IP 65 Protection degree 24 Red L...

Page 10: ...DMX signal connector IN 5 DMX signal connector OUT Installation Installing the LED Lights The Showtec LED City Painter 45 uses LED lights LED lights do not have to be replaced Damages caused by non ob...

Page 11: ...le to connect the City Painters and other devices The pins 1 Earth 2 Signal 3 Signal 3 Link the units as shown in figure 3 Connect a DMX signal cable from the first unit s DMX out socket to the second...

Page 12: ...e any overlapping channels in order to control each LED City Painter correctly If two or more LED City Painters are addressed similarly they will work similarly For address settings please refer to th...

Page 13: ...9 197 59 407 30 204 60 414 Colour temperature The CTC channel allows to adjust Palco s colour temperature It acts in a range around the white balance or Full Color according to requirements It s there...

Page 14: ...Green saturation adjustment 0 100 Channel 5 Blue 0 255 Linear Green saturation adjustment 0 100 Channel 6 CTC Color Correction 0 255 From Cold 2000 K to Warm 2000 k compared to balanced white or not C...

Page 15: ...13...

Page 16: ...NTER once you have the intensity you want You now return to the previous menu 7 If you want to exit the entire Colour Balance Menu press and hold down the ENTER button for six seconds 1 Use the UP DOW...

Page 17: ...ur setting and exit the BOOST menu Note Using BOOST means the overall lifetime of the LEDs goes from 100 000 to 50 000 hours No Function No Function No Function No Function 5 Input Signal The Signal m...

Page 18: ...tant to set the LED City Painter s internal clock for later use in Stand alone mode 1 Use the UP DOWN buttons to scroll through the display until it shows Time 2 Press and hold down the ENTER button f...

Page 19: ...ll show Red Press the ENTER button and the fixture will test the RED LEDs Press and hold down the ENTER button for six seconds to return to the previous menu 4 Use the UP DOWN buttons to select RED GR...

Page 20: ...to choose between ON or OFF 4 Press ENTER to store your setting and exit the Master menu 15 Configuring Slaves When multiple City Painters are connected in stand alone Mode one device has to be the m...

Page 21: ...UP Button to scroll through the menu until the display shows Dimmer 0 255 Use the UP DOWN buttons to change the value from 0 255 Press the ENTER button to store your setting and return to the previous...

Page 22: ...ntil it shows Sched1 2 Press the ENTER button and the display will show event 1 36 Use the UP DOWN buttons to change the value from 1 36 Press the ENTER button to store your setting and return to the...

Page 23: ...tribution Testing Circumstances Installation position horizontal Max Luminous intensity 4569 49 cd Luminous Flux 1640 01 lm Luminous Efficiency 17 50 lm w Source voltage 220 V Current Source 0 777 A P...

Page 24: ...Replacing a Fuse Power surges short circuit or inappropriate electrical power supply may cause a fuse to burn out If the fuse burns out the product will not function whatsoever If this happens follow...

Page 25: ...Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixtu...

Page 26: ...g DIP Switches DMX Channels 7 Signal input 3 pin XLR male Signal output 3 pin XLR female IP Protection Grade IP65 Electro mechanical effects DMX control via standard DMX controller Color effect 3 Colo...

Page 27: ......