![SHOWTEC LED City Painter 45 User Manual Download Page 14](http://html1.mh-extra.com/html/showtec/led-city-painter-45/led-city-painter-45_user-manual_1260462014.webp)
12
DMX Protocol
The LED City Painter 45 can be operated with a controller in
control mode
or without the controller in
stand-alone mode.
DMX Channels
Channel 1 – Shutter / Dimmer
0-3
Shutter closed
4-6
Open
7-59
Linear Strobe frequency adjustment from 1 to 20 Hz
60-78
Pulse open effect low speed
79-87
Pulse open effect medium speed
88-255
Pulse open effect high speed
Channel 2 – Dimmer intensity
0-255
Gradual adjustment dimmer intensity from 0-100%
Channel 3 – Red
0-255
Linear Red saturation adjustment 0 – 100 %
Channel 4 – Green
0-255
Linear Green saturation adjustment 0 – 100 %
Channel 5 – Blue
0-255
Linear Green saturation adjustment 0 – 100 %
Channel 6 – CTC Color Correction
0-255
From Cold + 2000 K° to Warm - 2000 k° compared to balanced white or not
Channel 7
– Shutter
0-7
No Macro
8-15
MACRO 1 Rainbow Slow - Stand Time 5 sec
16-23
MACRO 2 Rainbow Medium - Stand Time 5 sec
24-31
MACRO 3 Rainbow Fast - Stand Time 5 sec
32-39
MACRO 4 Rainbow Slow - NO Stand time
40-47
MACRO 5 Rainbow Medium - NO Stand time
48-55
MACRO 6 Rainbow Fast - NO Stand time
56-63
MACRO 7 Rainbow Very slow - NO Stand time
64-70
MACRO 8 Random Colour Slow
71
Store Colour_mode enable
72-79
MACRO 9 Random Color Medium
80-87
MACRO 10 Random Color Fast
88-95
Future
96-103
Future
104-111
Future
112-119
Future
120-136
Future