background image

 

  

 

 

   

 

Ordercode: 61000 

FX Ice Jet 

 

The user is responsible for correct positioning and operating of the FX Ice Jet. The manufacturer will 
not accept liability for damages caused by the misuse or incorrect installation of this device. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 
conductor to earth. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 

 

 

 

 

Operating Determinations 

 

This device is not designed for permanent operation. Consistent operation breaks will ensure that the 
device will serve you for a long time without defects. 

 

The maximum ambient temperature ta = 30°C must never be exceeded. 

 

Do not expose this device to relative humidity degree higher than 75%. 

 

Do not expose this device to any source of vibration. 

 

Operate the device in a reasonably stable temperature of between 0 and 30ºC 

 

If this device is operated in any other way, than the one described in this manual, the product may 
suffer damages and the warranty becomes void. 

 

If any unauthorized alterations or repairments are performed on the device, the warranty becomes 
void. 

 

Any operation different to the ones described in this manual may lead to dangers like frostbite,  
short-circuit, burns, electric shock, crash etc. 

 

Rigging 
Please follow the European and national guidelines concerning rigging, trussing and all 
other safety issues. 
 
Do not attempt the installation yourself ! 
Always let the installation be carried out by an authorized dealer ! 
 
Procedure: 

 

If the FX Ice Jet is lowered from the ceiling or high joists, professional trussing systems have to be used. 

 

Use a clamp to mount the FX Ice Jet, with the mounting-bracket, to the trussing system. 

 

The FX Ice Jet must never be fixed swinging freely in the room.  

 

The installation must always be secured with a safety attachment, e.g. an appropriate safety net or 
safety-cable. 

 

When rigging, derigging or servicing the FX Ice Jet, always make sure, that the area below the 
installation place is blocked and staying in the area is forbidden. 

 

 

We presume that you, your employees and others who come into contact with the FX Ice 
Jet are familiar with how the machine must be dealt with. This includes the correct use, 
maintenance and repair of the FX Ice Jet as described in this user manual. The employees 
should be familiar with the use of machines through training and/or experience. 

 

 

Improper installation can cause serious damage to people and property ! 

 

 

Summary of Contents for FX Ice Jet

Page 1: ...FX Ice Jet V2 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 61000 MANUAL ENGLISH...

Page 2: ...Overview 7 Optional accessories 8 Installation 9 Set Up and Operation 13 Usage 13 Switching Off 13 Declaration of Conformity 15 Maintenance 16 Troubleshooting 16 The FX Ice Jet is leaking 16 Only a sm...

Page 3: ...on and all packing materials In the event that a fixture must be returned to the factory it is important that the fixture be returned in the original factory box and packing Your shipment includes Sho...

Page 4: ...igher the humidity the longer the output distance Only use the device indoors avoid contact with water or other liquids Only operate the fixture after having checked that the housing is firmly closed...

Page 5: ...the warranty becomes void Any operation different to the ones described in this manual may lead to dangers like frostbite short circuit burns electric shock crash etc Rigging Please follow the Europe...

Page 6: ...of the machine Showtec is not liable for any consequential loss in the event of an FX Ice Jet breakdown This user manual has been drawn up with the utmost care Showtec cannot be held responsible for a...

Page 7: ...mber 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this che...

Page 8: ...oximately 8 meter long and depends strictly on current air humidity The higher the humidity the longer the smoke stream will be CO2 gas has a temperature of 70 degrees Features Input voltage 230 VAC 5...

Page 9: ...Ordercode 61000 FX Ice Jet Optional accessories 61010 CO2 High Pressure Hose 5 m 61011 CO2 High Pressure Hose 10 m 61012 CO2 High Pressure Hose 15 m 70332 Twenty Clamp SWL 20 kg T V 28 mm 61001 Ice Gu...

Page 10: ...In order to carry out a proper and safe installation act according to the following steps Step 1 01 Place the CO2 bottle on a stable and even surface and secure it by means of an approved strap or bo...

Page 11: ...change the direction of the output 02 Ensure at all times that the coupling of the cannon tube is firmly tightened with an open ended spanner Step 4 01 The FX Ice Jet is activated as soon as it is pow...

Page 12: ...f the system has been connected properly you will hear a clicking sound which is produced by the opening and closing of the magnetic valve in the FX Ice Jet Step 6 01 Connect the hose to the FX Ice Je...

Page 13: ...is properly connected open the valve of the CO2 bottle 02 Check for leaks 03 If the gas hose is not properly connected gas can escape 04 If this is the case turn the couplings tighter until gas is no...

Page 14: ...ty The higher the humidity the longer the smoke stream will be CO2 gas has a temperature of 70 degrees The proper use of the FX Ice Jet requires utmost safety and alertness In order to use the device...

Page 15: ...61000 FX Ice Jet 03 Disconnect the plug of the FX Ice Jet from the power supply preferably via a dimming pack 04 The hose can be disconnected from the gas bottle and the FX Ice Jet only when there is...

Page 16: ...15 Ordercode 61000 FX Ice Jet Declaration of Conformity...

Page 17: ...eformations on housings fixations and installation spots 03 The electric power supply cables must not show any damages or material fatigue Troubleshooting The FX Ice Jet is leaking 01 Check if the cou...

Page 18: ...Liquid CO2 Output CO2 gas Consumption CO2 30L min Quick connector RU 1 W21 8x1 14 3 8 BSP Electro mechanical effects IEC power IN Housing Black Metal Flame retardant plastic Output range 8 meters Max...

Page 19: ...18 Ordercode 61000 FX Ice Jet Dimensions...

Page 20: ...2019 Showtec...

Reviews: