background image

 

  

 

 

   

 

Ordercode: 61000 

FX Ice Jet 

Before your initial start-up, please make sure that there is no damage caused by transportation. Should 
there be any, consult your dealer and do not use the device. 
 
To maintain perfect condition and to ensure a safe operation, it is absolutely necessary for the user to 
follow the safety instructions and warning notes written in this manual. 
Please consider that damages caused by manual modifications to the device are not subject to 
warranty. 
This device contains no user-serviceable parts. Refer servicing to qualified technicians only. 
 

IMPORTANT: 

The manufacturer will not accept liability for any resulting damages caused by the non-observance of 
this manual or any unauthorized modification to the device. 
 

 

Never let the power cord come into contact with other cables! Handle the power cord and all 
connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit and, on regular basis, make sure that they 
remain clearly visible and legible. 

 

Never place any material over the cannon tube. 

 

Never look directly into the cannon tube. 

 

Never leave any cables lying around. 

 

Do not expose the device to any source of vibration. 

 

Do not insert objects into the cannon tube. 

 

Do not switch the device on and off in short intervals, as this would reduce the device’s life. 

 

Do not touch the device’s housing bare-handed during its operation. 

 

Do not remove or disable the safety devices. 

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

Use the device ONLY if there ARE NOT ANY people, animals or other objects in the direction of the 
output within the output range. The shooting direction is the direction in which the output pipe on 
the FX Ice Jet is pointed. The output distance depends on the humidity in the air! The higher the 
humidity, the longer the output distance. 

 

Only use the device indoors, avoid contact with water or other liquids. 

 

Only operate the fixture after having checked that the housing is firmly closed and all screws are 
tightly fastened. 

 

Only operate the device after having familiarized with its functions. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always keep case closed while operating. 

 

Always allow free air space of at least 50 cm around the unit for ventilation. 

 

Always disconnect power from the mains, when device is not used or before cleaning! Only handle 
the power cord by the plug. Never pull out the plug by tugging the power cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that all the required safety devices are in good condition and function properly. 

 

Make sure that the power cord is never crimped or damaged. Check the device and the power 
cord from time to time. 

 

If the cannon tube is obviously damaged, it needs to be replaced, so that its functions are not 
impaired. 

 

If the device is dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 
switch it on immediately. The arising condensation water might damage your device. Leave the 
device switched off until it has reached room temperature. 

 

If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely 
(preferably in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. Device must be installed out of the reach of children and unauthorized persons. 
Never leave the unit running unattended. 

 

Never attempt to bypass the thermostatic switch or fuses. 

 

For replacement use fuses of same type and rating only. 

 

Provide sufficient lighting of the surroundings. 

Summary of Contents for FX Ice Jet

Page 1: ...FX Ice Jet V2 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 61000 MANUAL ENGLISH...

Page 2: ...Overview 7 Optional accessories 8 Installation 9 Set Up and Operation 13 Usage 13 Switching Off 13 Declaration of Conformity 15 Maintenance 16 Troubleshooting 16 The FX Ice Jet is leaking 16 Only a sm...

Page 3: ...on and all packing materials In the event that a fixture must be returned to the factory it is important that the fixture be returned in the original factory box and packing Your shipment includes Sho...

Page 4: ...igher the humidity the longer the output distance Only use the device indoors avoid contact with water or other liquids Only operate the fixture after having checked that the housing is firmly closed...

Page 5: ...the warranty becomes void Any operation different to the ones described in this manual may lead to dangers like frostbite short circuit burns electric shock crash etc Rigging Please follow the Europe...

Page 6: ...of the machine Showtec is not liable for any consequential loss in the event of an FX Ice Jet breakdown This user manual has been drawn up with the utmost care Showtec cannot be held responsible for a...

Page 7: ...mber 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this che...

Page 8: ...oximately 8 meter long and depends strictly on current air humidity The higher the humidity the longer the smoke stream will be CO2 gas has a temperature of 70 degrees Features Input voltage 230 VAC 5...

Page 9: ...Ordercode 61000 FX Ice Jet Optional accessories 61010 CO2 High Pressure Hose 5 m 61011 CO2 High Pressure Hose 10 m 61012 CO2 High Pressure Hose 15 m 70332 Twenty Clamp SWL 20 kg T V 28 mm 61001 Ice Gu...

Page 10: ...In order to carry out a proper and safe installation act according to the following steps Step 1 01 Place the CO2 bottle on a stable and even surface and secure it by means of an approved strap or bo...

Page 11: ...change the direction of the output 02 Ensure at all times that the coupling of the cannon tube is firmly tightened with an open ended spanner Step 4 01 The FX Ice Jet is activated as soon as it is pow...

Page 12: ...f the system has been connected properly you will hear a clicking sound which is produced by the opening and closing of the magnetic valve in the FX Ice Jet Step 6 01 Connect the hose to the FX Ice Je...

Page 13: ...is properly connected open the valve of the CO2 bottle 02 Check for leaks 03 If the gas hose is not properly connected gas can escape 04 If this is the case turn the couplings tighter until gas is no...

Page 14: ...ty The higher the humidity the longer the smoke stream will be CO2 gas has a temperature of 70 degrees The proper use of the FX Ice Jet requires utmost safety and alertness In order to use the device...

Page 15: ...61000 FX Ice Jet 03 Disconnect the plug of the FX Ice Jet from the power supply preferably via a dimming pack 04 The hose can be disconnected from the gas bottle and the FX Ice Jet only when there is...

Page 16: ...15 Ordercode 61000 FX Ice Jet Declaration of Conformity...

Page 17: ...eformations on housings fixations and installation spots 03 The electric power supply cables must not show any damages or material fatigue Troubleshooting The FX Ice Jet is leaking 01 Check if the cou...

Page 18: ...Liquid CO2 Output CO2 gas Consumption CO2 30L min Quick connector RU 1 W21 8x1 14 3 8 BSP Electro mechanical effects IEC power IN Housing Black Metal Flame retardant plastic Output range 8 meters Max...

Page 19: ...18 Ordercode 61000 FX Ice Jet Dimensions...

Page 20: ...2019 Showtec...

Reviews: