background image

 

Connection with the mains

 

Connect the device to the mains with the power-plug. 
Always pay attention, that the right color cable is connected to the right place.

 

 

International 

EU Cable 

UK Cable 

US Cable 

Pin 

BROWN 

RED 

YELLOW/COPPER 

FASE 

BLUE 

BLACK 

SILVER 

NUL 

 

YELLOW/GREEN 

GREEN 

GREEN 

EARTH 

 

 

Make sure that the device is always connected 

properly

 to the earth!  

 
 
 
 
 
 
 
 
 
 
 

Return Procedure 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

[email protected]

 and request an RMA prior to shipping the fixture. 

Be prepared to provide the model number, serial number and a brief description of the cause for the 
return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the 
customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 
 

Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 

1) Your name 
2) Your address 
3) Your phone number 
4) A brief description of the symptoms 
 
 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
 It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery.  
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
otherwise agreed in writing. 
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the 
invoice. After this period complaints will not be handled anymore. 
Complaints will only then be considered if the client has so far complied with all parts of the agreement, 
regardless of the agreement of which the obligation is resulting.  
 

 

Summary of Contents for Cameleon Spot 18-4 Q4

Page 1: ...Cameleon Spot 18 4 Q4 ORDERCODE 42692...

Page 2: ...esign and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied For more information iwant s...

Page 3: ...Spot Built in Programs 8 Multiple Cameleon Spots Master Slave control 8 Multiple Cameleon Spots DMX Control 9 Fixture Linking 10 Data Cabling 10 Control Panel 11 DMX Control Mode 11 DMX Addressing 11...

Page 4: ...conditions If improving on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may include climatic environmental and the reduction of over...

Page 5: ...power cord is never crimped or damaged Check the device and the power cord from time to time If the external cable is damaged it has to be replaced by a qualified technician If the lens is obviously...

Page 6: ...es Do not attempt the installation yourself Always let the installation be carried out by an authorized dealer Procedure If the Cameleon Spot 18 4 Q4 is lowered from the ceiling or high joists profess...

Page 7: ...od to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 A brief description of the sy...

Page 8: ...ed IP65 connector Schuko to IP powercable included Lens Plate Tempered Glass Display LED display for auto and custom control Control DMX Auto Program Master slave Manual Dimmer 0 100 Strobe 0 20Hz Bea...

Page 9: ...7 Overview 1 2 Fig 1 1 Mountingbracket with adjustment screw 2 18x 4 in 1 4W RGBW LEDs Backside Fig 2 3 4 5 6 7 3 Power In 6 3 pin DMX Out 4 3 pin DMX In 7 Power Out 5 LCD Display Menu Buttons...

Page 10: ...by a DMX cable it functions as a stand alone device Please see page 13 for more information about the Manual Color control One Cameleon Spot Built in Programs 1 Fasten the effect light onto firm trus...

Page 11: ...e from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth units 5 Supply electric power Plug the end of the mains power cord into pr...

Page 12: ...er may result in deterioration of the digital DMX signal Maximum recommended DMX data link distance 100 meters Maximum recommended number of Cameleon Spots on a DMX data link 30 fixtures Data Cabling...

Page 13: ...trol each Cameleon Spot correctly If two or more Cameleon Spots are addressed similarly they will work similarly For address settings please refer to the instructions under Addressing menu d001 Contro...

Page 14: ...12 Menu Overview 1 DMX Address 2 Manual Color 3 Auto Program 4 Built in Programs 5 Slave...

Page 15: ...SETUP button to set 4 different DMX Modes Use the Up Down buttons to select the required Mode 4 Channel 6 Channels 8 Channels 2 Manual colors With this menu you can manually set a desired color 1 Pre...

Page 16: ...Frequency from 00 99 Red 20 Green 80 Flash Frequency from 00 99 Green Flash Frequency from 00 99 Green Blue Flash Frequency from 00 99 Blue Flash Frequency from 00 99 Red 80 Blue 20 Flash Frequency fr...

Page 17: ...Green gradual color brightness from 0 to 100 Channel 3 Blue 0 255 Blue gradual color brightness from 0 to 100 Channel 4 White 0 255 White gradual color brightness from 0 to 100 6 Channels Channel 1 Re...

Page 18: ...4 color gradual change R G B W 54 80 Program 3 10 color gradual change 81 107 Program 4 4 color fantasy change 108 134 Program 5 4 color color switch R G B W 135 161 Program 6 10 color color switch 1...

Page 19: ...c power supply cables must not show any damages or material fatigue Troubleshooting No Light This troubleshooting guide is meant to help solve simple problems If a problem occurs carry out the steps b...

Page 20: ...tion plug or a defective fixture disturbing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120...

Page 21: ...owerconnector DMX Connection Dedicated IP65 connector Schuko to IP powercable included Lens Plate Tempered Glass Display LED display for auto and custom control Control DMX Auto Program Master slave M...

Page 22: ......