Control Panel

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

 

 

 

 

 

 

 

 

 

Fig. 5

 

 

 

A.

 LED Display   

 

D.

 Up Button 

B.

 MODE Button 

 

E.

 Down Button 

C.

 SETUP Button

  

 

 

 

 

DMX Control Mode

  

The fixtures are individually addressed on a data-link and connected to the controller.  
The fixtures respond to the DMX signal from the controller.

 

 

DMX Addressing

 

The control panel on the front side of the base allows you to assign the DMX fixture address, which is the 
first channel from which the Cameleon Spot will respond to the controller. 
Please note when you use the controller, the unit has max. 

8

 channels. 

When using multiple Cameleon Spots, make sure you set the DMX addresses right. 
Therefore, the DMX address of the first Cameleon Spot should be 

1(001)

; the DMX address of the second 

Cameleon Spot should be 

1+8=9

; the DMX address of the third Cameleon Spot should be 

9+8=17

, etc. 

Please, be sure that you don’t have any overlapping channels in order to control each Cameleon Spot 
correctly. If two or more Cameleon Spots are addressed similarly, they will work similarly.

 

For address settings, please refer to the instructions under ”Addressing’ (menu d001)

 

 

Controlling: 

After having addressed all Cameleon Spots, you may now start operating these via your lighting 
controller.

 

Note:

 After switching on, the Cameleon Spot will automatically detect whether DMX 512 data is received 

or not. 

 

If not, the problem may be:

 

 

The XLR cable from the controller is not connected with the input of the Cameleon Spot.

 

 

The controller is switched off or defective, the cable or connector is detective, or the signal wires are 
swapped in the input connector. 

 

Note: 

It’s necessary to insert a XLR termination plug (with 120 Ohm) in the last fixture in order to ensure 

proper transmission on the DMX data link. 

 

 

      Display Off after 20 seconds 

When no button is pressed for 20 seconds, the display will be locked. 
To unlock the display you have to simultaneously press the first (MODE) and fourth (DOWN) button. 
Once you have pressed both buttons, the display will light up. 

 

Summary of Contents for Cameleon Spot 18-4 Q4

Page 1: ...Cameleon Spot 18 4 Q4 ORDERCODE 42692...

Page 2: ...esign and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied For more information iwant s...

Page 3: ...Spot Built in Programs 8 Multiple Cameleon Spots Master Slave control 8 Multiple Cameleon Spots DMX Control 9 Fixture Linking 10 Data Cabling 10 Control Panel 11 DMX Control Mode 11 DMX Addressing 11...

Page 4: ...conditions If improving on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may include climatic environmental and the reduction of over...

Page 5: ...power cord is never crimped or damaged Check the device and the power cord from time to time If the external cable is damaged it has to be replaced by a qualified technician If the lens is obviously...

Page 6: ...es Do not attempt the installation yourself Always let the installation be carried out by an authorized dealer Procedure If the Cameleon Spot 18 4 Q4 is lowered from the ceiling or high joists profess...

Page 7: ...od to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 A brief description of the sy...

Page 8: ...ed IP65 connector Schuko to IP powercable included Lens Plate Tempered Glass Display LED display for auto and custom control Control DMX Auto Program Master slave Manual Dimmer 0 100 Strobe 0 20Hz Bea...

Page 9: ...7 Overview 1 2 Fig 1 1 Mountingbracket with adjustment screw 2 18x 4 in 1 4W RGBW LEDs Backside Fig 2 3 4 5 6 7 3 Power In 6 3 pin DMX Out 4 3 pin DMX In 7 Power Out 5 LCD Display Menu Buttons...

Page 10: ...by a DMX cable it functions as a stand alone device Please see page 13 for more information about the Manual Color control One Cameleon Spot Built in Programs 1 Fasten the effect light onto firm trus...

Page 11: ...e from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth units 5 Supply electric power Plug the end of the mains power cord into pr...

Page 12: ...er may result in deterioration of the digital DMX signal Maximum recommended DMX data link distance 100 meters Maximum recommended number of Cameleon Spots on a DMX data link 30 fixtures Data Cabling...

Page 13: ...trol each Cameleon Spot correctly If two or more Cameleon Spots are addressed similarly they will work similarly For address settings please refer to the instructions under Addressing menu d001 Contro...

Page 14: ...12 Menu Overview 1 DMX Address 2 Manual Color 3 Auto Program 4 Built in Programs 5 Slave...

Page 15: ...SETUP button to set 4 different DMX Modes Use the Up Down buttons to select the required Mode 4 Channel 6 Channels 8 Channels 2 Manual colors With this menu you can manually set a desired color 1 Pre...

Page 16: ...Frequency from 00 99 Red 20 Green 80 Flash Frequency from 00 99 Green Flash Frequency from 00 99 Green Blue Flash Frequency from 00 99 Blue Flash Frequency from 00 99 Red 80 Blue 20 Flash Frequency fr...

Page 17: ...Green gradual color brightness from 0 to 100 Channel 3 Blue 0 255 Blue gradual color brightness from 0 to 100 Channel 4 White 0 255 White gradual color brightness from 0 to 100 6 Channels Channel 1 Re...

Page 18: ...4 color gradual change R G B W 54 80 Program 3 10 color gradual change 81 107 Program 4 4 color fantasy change 108 134 Program 5 4 color color switch R G B W 135 161 Program 6 10 color color switch 1...

Page 19: ...c power supply cables must not show any damages or material fatigue Troubleshooting No Light This troubleshooting guide is meant to help solve simple problems If a problem occurs carry out the steps b...

Page 20: ...tion plug or a defective fixture disturbing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120...

Page 21: ...owerconnector DMX Connection Dedicated IP65 connector Schuko to IP powercable included Lens Plate Tempered Glass Display LED display for auto and custom control Control DMX Auto Program Master slave M...

Page 22: ......

Reviews: