IMPORTANT:

 

The manufacturer will not accept liability for any resulting damages caused by the non-
observance of this manual or any unauthorized modification to the device. 

 

 

Never let the power-cord come into contact with other cables! Handle the power-cord and all 
connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Never leave any cables lying around. 

 

Do not insert objects into air vents. 

 

Do not connect this device to a dimmerpack. 

 

Do not open the device and do not modify the device. 

 

Never use the device during thunderstorms, unplug the device immediately. 

 

Never look directly into the light source. 

 

Do not switch the device on and off in short intervals, as this would reduce the system’s life. 

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

Only use device indoor, avoid contact with water or other liquids. 

 

Only operate the fixture after having checked that the housing is firmly closed and all screws are 
tightly fastened. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always allow free air space of at least 50 cm around the unit for ventilation. 

 

Always disconnect power from the mains, when device is not used or before cleaning! Only 
handle the power-cord by the plug. Never pull out the plug by tugging the power-cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power-cord is never crimped or damaged. Check the device and the power-
cord from time to time. 

 

If the external cable is damaged, it has to be replaced by a qualified technician. 

 

If the lens is obviously damaged, it has to be replaced. So that its functions are not impaired, due 
to cracks or deep scratches. 

 

If device is dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do 
not switch it on immediately. The arising condensation water might damage your device. Leave 
the device switched off until it has reached room temperature. 

 

If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely 
(preferably in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. Light effect must be installed out of the reach of children. Never leave the unit 
running unattended. 

 

For replacement use fuses of same type and rating only. 

 

The user is responsible for correct positioning and operating of the Cameleon Spot 18-4 Q4. The 
manufacturer will not accept liability for damages caused by the misuse or incorrect installation 
of this device. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 
conductor to earth. 

 

During the initial start-up some smoke or smell may arise. This is a normal process and does not 
necessarily mean that the device is defective. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase.

 

 
 
 
 

 

 

CAUTION ! EYEDAMAGES !. 

Avoid looking directly into the light source. 

(meant especially for epileptics) !

 

 

Summary of Contents for Cameleon Spot 18-4 Q4

Page 1: ...Cameleon Spot 18 4 Q4 ORDERCODE 42692...

Page 2: ...esign and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied For more information iwant s...

Page 3: ...Spot Built in Programs 8 Multiple Cameleon Spots Master Slave control 8 Multiple Cameleon Spots DMX Control 9 Fixture Linking 10 Data Cabling 10 Control Panel 11 DMX Control Mode 11 DMX Addressing 11...

Page 4: ...conditions If improving on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may include climatic environmental and the reduction of over...

Page 5: ...power cord is never crimped or damaged Check the device and the power cord from time to time If the external cable is damaged it has to be replaced by a qualified technician If the lens is obviously...

Page 6: ...es Do not attempt the installation yourself Always let the installation be carried out by an authorized dealer Procedure If the Cameleon Spot 18 4 Q4 is lowered from the ceiling or high joists profess...

Page 7: ...od to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 A brief description of the sy...

Page 8: ...ed IP65 connector Schuko to IP powercable included Lens Plate Tempered Glass Display LED display for auto and custom control Control DMX Auto Program Master slave Manual Dimmer 0 100 Strobe 0 20Hz Bea...

Page 9: ...7 Overview 1 2 Fig 1 1 Mountingbracket with adjustment screw 2 18x 4 in 1 4W RGBW LEDs Backside Fig 2 3 4 5 6 7 3 Power In 6 3 pin DMX Out 4 3 pin DMX In 7 Power Out 5 LCD Display Menu Buttons...

Page 10: ...by a DMX cable it functions as a stand alone device Please see page 13 for more information about the Manual Color control One Cameleon Spot Built in Programs 1 Fasten the effect light onto firm trus...

Page 11: ...e from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth units 5 Supply electric power Plug the end of the mains power cord into pr...

Page 12: ...er may result in deterioration of the digital DMX signal Maximum recommended DMX data link distance 100 meters Maximum recommended number of Cameleon Spots on a DMX data link 30 fixtures Data Cabling...

Page 13: ...trol each Cameleon Spot correctly If two or more Cameleon Spots are addressed similarly they will work similarly For address settings please refer to the instructions under Addressing menu d001 Contro...

Page 14: ...12 Menu Overview 1 DMX Address 2 Manual Color 3 Auto Program 4 Built in Programs 5 Slave...

Page 15: ...SETUP button to set 4 different DMX Modes Use the Up Down buttons to select the required Mode 4 Channel 6 Channels 8 Channels 2 Manual colors With this menu you can manually set a desired color 1 Pre...

Page 16: ...Frequency from 00 99 Red 20 Green 80 Flash Frequency from 00 99 Green Flash Frequency from 00 99 Green Blue Flash Frequency from 00 99 Blue Flash Frequency from 00 99 Red 80 Blue 20 Flash Frequency fr...

Page 17: ...Green gradual color brightness from 0 to 100 Channel 3 Blue 0 255 Blue gradual color brightness from 0 to 100 Channel 4 White 0 255 White gradual color brightness from 0 to 100 6 Channels Channel 1 Re...

Page 18: ...4 color gradual change R G B W 54 80 Program 3 10 color gradual change 81 107 Program 4 4 color fantasy change 108 134 Program 5 4 color color switch R G B W 135 161 Program 6 10 color color switch 1...

Page 19: ...c power supply cables must not show any damages or material fatigue Troubleshooting No Light This troubleshooting guide is meant to help solve simple problems If a problem occurs carry out the steps b...

Page 20: ...tion plug or a defective fixture disturbing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120...

Page 21: ...owerconnector DMX Connection Dedicated IP65 connector Schuko to IP powercable included Lens Plate Tempered Glass Display LED display for auto and custom control Control DMX Auto Program Master slave M...

Page 22: ......

Reviews: