Cameleon Flood 15 Q4 

Channel 6 – Auto speed (CH5 must be set between 41-255 

 ) 

0-255 

Speed adjustment, from slow to fast 

 

Channel 7 – Red Dimmer intensity (CH1 must be set between 1-255

 

 ) 

0-255 

Gradual adjustment Red from 0-100% 

 

Channel 8 – Green Dimmer intensity ( CH1 must be set between 1-255

 

 ) 

0-255 

Gradual adjustment Green from 0-100% 

 

Channel 9 – Blue Dimmer intensity (CH1 must be set between 1-255

 

 ) 

0-255 

Gradual adjustment Blue from 0-100% 

 

Channel 10 – White Dimmer intensity (CH1 must be set between 1-255

 

 ) 

0-255 

Gradual adjustment White from 0-100% 

 
 

Maintenance 

The operator has to make sure that safety-related and machine-technical installations are to be 
inspected by an expert after every year in the course of an acceptance test. 
The operator has to make sure that safety-related and machine-technical installations are to be 
inspected by a skilled person once a year. 
 
The following points have to be considered during the inspection: 
01)

 

All screws used for installing the device or parts of the device have to be tightly connected and 
must not be corroded. 

02)

 

There may not be any deformations on housings, fixations and installation spots. 

03)

 

Mechanically moving parts like axles, eyes and others may not show any traces of wearing. 

04)

 

The electric power supply cables must not show any damages or material fatigue. 

 

The Cameleon Flood 15 Q4 requires almost no maintenance. However, you should keep the unit clean.  
Otherwise, the fixture’s light-output will be significantly reduced. Disconnect the mains power supply, and 
then wipe the cover with a damp cloth. Do not immerse in liquid. Wipe lens clean with glass cleaner and 
a soft cloth. Do not use alcohol or solvents. 
The front lens will require weekly cleaning, as smoke-fluid tends to build up residues, reducing the light-
output very quickly. 
Keep connections clean. Make sure connections are thoroughly dry before linking equipment or 
supplying electric power. 
 

Troubleshooting 

This troubleshooting guide is meant to help solve simple problems.  
If a problem occurs, carry out the steps below in sequence until a solution is found. Once the unit 
operates properly, do not carry out following steps. 
 

No Light 

If the light effect does not operate properly, refer servicing to a technician. 
Suspect three potential problem areas as: the power supply, the LEDs, the internal fuse. 
01)

 

Power supply. Check that the unit is plugged into an appropriate power supply. 

02)

 

The LEDs. Return the Cameleon Flood to your Showtec dealer. 

03)

 

The internal fuse. Return the Cameleon Flood to your Showtec dealer. 

04)

 

If all of the above appears to be O.K., plug the unit in again. 

05)

 

If you are unable to determine the cause of the problem, do not open the Cameleon Flood, as this 
may damage the unit and the warranty will become void. 

06)

 

Return the device to your Showtec dealer. 

 

 

Summary of Contents for Cameleon Flood 15 Q4

Page 1: ...Cameleon Flood 15 Q4 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 42671 MANUAL ENGLISH...

Page 2: ...eon Floods Master Slave control 10 Multiple Cameleon Floods DMX Control 11 Fixture Linking 12 Data Cabling 12 Control Panel 13 Control Mode 13 DMX Addressing 13 Menu Overview 14 Main Menu Options 15 1...

Page 3: ...Showtec Cameleon Flood 15 Q4 1x Schuko to 3 pins IP 65 Power cable 1 5m User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor that leads to the a...

Page 4: ...efore handling Do not shake the device Avoid brute force when installing or operating the device Only use the device indoors avoid contact with water or other liquids Only operate the fixture after ha...

Page 5: ...emperature of 40 C If this device is operated in any other way than the one described in this manual the product may suffer damages and the warranty becomes void Any other operation may lead to danger...

Page 6: ...n with the mains Connect the device to the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELL...

Page 7: ...number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this c...

Page 8: ...n White 1505 Lumen Full Output 3434 Lumen Beam Angle 25 Max distance 20m Protection rate IP 65 Lens Plate Tempered Glass Control DMX Auto Program Built in programs Master slave Manual Dimmer 0 100 Str...

Page 9: ...RGBW ProLight Opto Hornet Series 02 Mounting bracket Backside Fig 02 03 Special mini 3 pin DMX cable IN IP 65 04 Special mini 3 pin DMX cable OUT IP 65 05 Special mini 3 pin power cable IN IP 65 06 O...

Page 10: ...rcode 70140 70141 03 Plug the end of the electric mains power cord into a proper electric power supply socket 04 When the Cameleon Flood is not connected with a DMX cable it functions as a stand alone...

Page 11: ...Link the units as shown in Fig 03 Connect the first unit s DMX out socket with the second unit s in socket using the 42707 427076 DMX Extension cable Link the second and third units using the 42707 42...

Page 12: ...it s in socket using the 42707 427076 DMX Extension cable Link the second and third units using the 42707 427076 DMX Extension cable 05 Supply electric power Plug electric mains power cords into each...

Page 13: ...Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can carry a high quality signal and a...

Page 14: ...e third Cameleon should be 11 10 21 021 etc Please be sure that you do not have any overlapping channels in order to control each Cameleon correctly If two or more Cameleons are addressed similarly th...

Page 15: ...14 Ordercode 42671 Cameleon Flood 15 Q4 Menu Overview...

Page 16: ...s the UP DOWN buttons to choose Program 02 Press the SET button to open the menu 03 Press the UP DOWN buttons to choose between Mode Color Speed or Strobe 04 Once you have chosen Mode press the SET bu...

Page 17: ...nu 07 Press the UP DOWN buttons to choose 4 6 or 10 DMX channels 4 Master slave With this menu you can set the device as a slave 01 While in the main menu press the UP DOWN buttons to choose Slave 02...

Page 18: ...adjust the dimming of the device by choosing a dimming curve 01 While in Settings menu press the UP DOWN buttons to choose Curves Select 02 Press the SET button to open the menu 03 Press the UP DOWN...

Page 19: ...r the safety lock is active 01 While in Settings menu press the UP DOWN buttons to choose Lock 02 Press the SET button to open the menu 03 Press the UP DOWN buttons to choose the desired option 04 You...

Page 20: ...ust be set between 1 255 0 255 Gradual adjustment Red from 0 100 Channel 4 Green Dimmer intensity CH1 must be set between 1 255 0 255 Gradual adjustment Green from 0 100 Channel 5 Blue Dimmer intensit...

Page 21: ...126 132 Color 18 R000 G000 B255 W100 133 139 Color 19 R000 G000 B255 W050 140 146 Color 20 R000 G000 B255 W000 147 153 Color 21 R075 G000 B255 W000 154 160 Color 22 R160 G000 B255 W000 161 167 Color 2...

Page 22: ...ages or material fatigue The Cameleon Flood 15 Q4 requires almost no maintenance However you should keep the unit clean Otherwise the fixture s light output will be significantly reduced Disconnect th...

Page 23: ...tically or not at all to the controller Poor data quality Check data quality If much lower than 100 percent the problem may be a bad data link connection poor quality or broken cables missing terminat...

Page 24: ...GBW ProLight Opto Hornet Series Lux 2m Red 800 Lumen Green 1040 Lumen Blue 328 Lumen White 1505 Lumen Full Output 3434 Lumen Beam angle 25 Max distance 20m Colour range 16 7 million additive colors RG...

Page 25: ...24 Ordercode 42671 Cameleon Flood 15 Q4 Dimensions...

Page 26: ...25 Ordercode 42671 Cameleon Flood 15 Q4 Notes...

Page 27: ...26 Ordercode 42671 Cameleon Flood 15 Q4...

Page 28: ...2017 Showtec...

Reviews: