background image

 

  

 

 

13 

   

 

Ordercode: 42671 

 

Cameleon Flood 15 Q4 

Control Panel 

 

 

A)  O-LED Display 
B)  MODE button 
C)  SET button 
D)  UP button 
E)   DOWN button 

 
 

Fig. 05 

 

 

 

Control Mode 

The fixtures are individually addressed on a data-link and connected to the controller.  
The fixtures respond to the DMX signal from the controller. (When you select the DMX address and save it, 
the controller will display the saved DMX address, next time.) 
 

DMX Addressing 

The control panel on the front side of the base allows you to assign DMX fixture addresses, which is the first 
channel with which the Cameleon will respond to the controller. 
Please note, when you use the controller, the unit has 

10

 channels. 

When using multiple Cameleons, make sure you set the DMX addresses right. 
Therefore, the DMX address of the first Cameleon should be 

1(001)

; the DMX address of the second 

Cameleon should be 

1+10=11 (011)

; the DMX address of the third Cameleon should be 

11+10=21 (021)

etc. Please, be sure that you do not have any overlapping channels in order to control each Cameleon 
correctly. If two or more Cameleons are addressed similarly, they will work similarly. 

 

Controlling: 

After having addressed all Cameleon fixtures, you may now start operating these via your lighting 
controller.

 

Note:

 After switching on, the Cameleon will automatically detect whether DMX 512 data is received or 

not. If not, the problem may be:

 

 

The XLR cable from the controller is not connected with the input of the Cameleon.

 

 

The controller is switched off or defective, the cable or connector is detective, or the signal wires are 
swapped in the input connector. 

 
Note: 

It is necessary to insert an XLR termination plug (with 120 Ohm) in the last fixture in order to ensure 

proper transmission on the DMX data link.  
 

 

Display Off after 50 seconds

 

 

When no button is pressed for 50 seconds, the display will turn off. 
To light up the display, you have to press the 

MODE

SET

UP

 or 

DOWN

 button. 

Once you have pressed the button, the display will light up. 

Summary of Contents for Cameleon Flood 15 Q4

Page 1: ...Cameleon Flood 15 Q4 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 42671 MANUAL ENGLISH...

Page 2: ...eon Floods Master Slave control 10 Multiple Cameleon Floods DMX Control 11 Fixture Linking 12 Data Cabling 12 Control Panel 13 Control Mode 13 DMX Addressing 13 Menu Overview 14 Main Menu Options 15 1...

Page 3: ...Showtec Cameleon Flood 15 Q4 1x Schuko to 3 pins IP 65 Power cable 1 5m User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor that leads to the a...

Page 4: ...efore handling Do not shake the device Avoid brute force when installing or operating the device Only use the device indoors avoid contact with water or other liquids Only operate the fixture after ha...

Page 5: ...emperature of 40 C If this device is operated in any other way than the one described in this manual the product may suffer damages and the warranty becomes void Any other operation may lead to danger...

Page 6: ...n with the mains Connect the device to the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELL...

Page 7: ...number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this c...

Page 8: ...n White 1505 Lumen Full Output 3434 Lumen Beam Angle 25 Max distance 20m Protection rate IP 65 Lens Plate Tempered Glass Control DMX Auto Program Built in programs Master slave Manual Dimmer 0 100 Str...

Page 9: ...RGBW ProLight Opto Hornet Series 02 Mounting bracket Backside Fig 02 03 Special mini 3 pin DMX cable IN IP 65 04 Special mini 3 pin DMX cable OUT IP 65 05 Special mini 3 pin power cable IN IP 65 06 O...

Page 10: ...rcode 70140 70141 03 Plug the end of the electric mains power cord into a proper electric power supply socket 04 When the Cameleon Flood is not connected with a DMX cable it functions as a stand alone...

Page 11: ...Link the units as shown in Fig 03 Connect the first unit s DMX out socket with the second unit s in socket using the 42707 427076 DMX Extension cable Link the second and third units using the 42707 42...

Page 12: ...it s in socket using the 42707 427076 DMX Extension cable Link the second and third units using the 42707 427076 DMX Extension cable 05 Supply electric power Plug electric mains power cords into each...

Page 13: ...Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can carry a high quality signal and a...

Page 14: ...e third Cameleon should be 11 10 21 021 etc Please be sure that you do not have any overlapping channels in order to control each Cameleon correctly If two or more Cameleons are addressed similarly th...

Page 15: ...14 Ordercode 42671 Cameleon Flood 15 Q4 Menu Overview...

Page 16: ...s the UP DOWN buttons to choose Program 02 Press the SET button to open the menu 03 Press the UP DOWN buttons to choose between Mode Color Speed or Strobe 04 Once you have chosen Mode press the SET bu...

Page 17: ...nu 07 Press the UP DOWN buttons to choose 4 6 or 10 DMX channels 4 Master slave With this menu you can set the device as a slave 01 While in the main menu press the UP DOWN buttons to choose Slave 02...

Page 18: ...adjust the dimming of the device by choosing a dimming curve 01 While in Settings menu press the UP DOWN buttons to choose Curves Select 02 Press the SET button to open the menu 03 Press the UP DOWN...

Page 19: ...r the safety lock is active 01 While in Settings menu press the UP DOWN buttons to choose Lock 02 Press the SET button to open the menu 03 Press the UP DOWN buttons to choose the desired option 04 You...

Page 20: ...ust be set between 1 255 0 255 Gradual adjustment Red from 0 100 Channel 4 Green Dimmer intensity CH1 must be set between 1 255 0 255 Gradual adjustment Green from 0 100 Channel 5 Blue Dimmer intensit...

Page 21: ...126 132 Color 18 R000 G000 B255 W100 133 139 Color 19 R000 G000 B255 W050 140 146 Color 20 R000 G000 B255 W000 147 153 Color 21 R075 G000 B255 W000 154 160 Color 22 R160 G000 B255 W000 161 167 Color 2...

Page 22: ...ages or material fatigue The Cameleon Flood 15 Q4 requires almost no maintenance However you should keep the unit clean Otherwise the fixture s light output will be significantly reduced Disconnect th...

Page 23: ...tically or not at all to the controller Poor data quality Check data quality If much lower than 100 percent the problem may be a bad data link connection poor quality or broken cables missing terminat...

Page 24: ...GBW ProLight Opto Hornet Series Lux 2m Red 800 Lumen Green 1040 Lumen Blue 328 Lumen White 1505 Lumen Full Output 3434 Lumen Beam angle 25 Max distance 20m Colour range 16 7 million additive colors RG...

Page 25: ...24 Ordercode 42671 Cameleon Flood 15 Q4 Dimensions...

Page 26: ...25 Ordercode 42671 Cameleon Flood 15 Q4 Notes...

Page 27: ...26 Ordercode 42671 Cameleon Flood 15 Q4...

Page 28: ...2017 Showtec...

Reviews: