background image

 

  

 

 

   

 

Ordercode: 42671 

 

Cameleon Flood 15 Q4 

Warning 

 

 

 

Unpacking Instructions 

Immediately upon receiving this product, carefully unpack the carton and check the contents to ensure 
that all parts are present, and have been received in good condition. Notify the dealer immediately and 
retain packing material for inspection if any parts appear damaged from shipping or the carton itself 
shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture must be 
returned to the factory, it is important that the fixture be returned in the original factory box and packing. 
 

Your shipment includes: 

 

 

 
 

 

 

Showtec Cameleon Flood 15 Q4 

 

1x Schuko to 3-pins (IP-65 ) Power 
cable 1,5m 

 

User manual 

 
 
 

 

LED Expected Lifespan 

LEDs gradually decline in brightness over time. HEAT is the dominant factor that leads to the acceleration 
of this decline. Packaged in clusters, LEDs exhibit higher operating temperatures than in ideal or singular 
optimum conditions. For this reason, when all color LEDs are used at their fullest intensity, life of the LEDs is 
significantly reduced. If improving the lifespan is of higher priority, place care in providing for lower 
operational temperatures. This may include climatic-environmental and the reduction of overall 
projection intensity. 
 

 

 

Safety Instructions 

Every person involved with the installation, operation and maintenance of this device has to: 

 

be qualified 

 

follow the instructions of this manual 

 

 

 

 

Summary of Contents for Cameleon Flood 15 Q4

Page 1: ...Cameleon Flood 15 Q4 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 42671 MANUAL ENGLISH...

Page 2: ...eon Floods Master Slave control 10 Multiple Cameleon Floods DMX Control 11 Fixture Linking 12 Data Cabling 12 Control Panel 13 Control Mode 13 DMX Addressing 13 Menu Overview 14 Main Menu Options 15 1...

Page 3: ...Showtec Cameleon Flood 15 Q4 1x Schuko to 3 pins IP 65 Power cable 1 5m User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor that leads to the a...

Page 4: ...efore handling Do not shake the device Avoid brute force when installing or operating the device Only use the device indoors avoid contact with water or other liquids Only operate the fixture after ha...

Page 5: ...emperature of 40 C If this device is operated in any other way than the one described in this manual the product may suffer damages and the warranty becomes void Any other operation may lead to danger...

Page 6: ...n with the mains Connect the device to the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELL...

Page 7: ...number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this c...

Page 8: ...n White 1505 Lumen Full Output 3434 Lumen Beam Angle 25 Max distance 20m Protection rate IP 65 Lens Plate Tempered Glass Control DMX Auto Program Built in programs Master slave Manual Dimmer 0 100 Str...

Page 9: ...RGBW ProLight Opto Hornet Series 02 Mounting bracket Backside Fig 02 03 Special mini 3 pin DMX cable IN IP 65 04 Special mini 3 pin DMX cable OUT IP 65 05 Special mini 3 pin power cable IN IP 65 06 O...

Page 10: ...rcode 70140 70141 03 Plug the end of the electric mains power cord into a proper electric power supply socket 04 When the Cameleon Flood is not connected with a DMX cable it functions as a stand alone...

Page 11: ...Link the units as shown in Fig 03 Connect the first unit s DMX out socket with the second unit s in socket using the 42707 427076 DMX Extension cable Link the second and third units using the 42707 42...

Page 12: ...it s in socket using the 42707 427076 DMX Extension cable Link the second and third units using the 42707 427076 DMX Extension cable 05 Supply electric power Plug electric mains power cords into each...

Page 13: ...Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can carry a high quality signal and a...

Page 14: ...e third Cameleon should be 11 10 21 021 etc Please be sure that you do not have any overlapping channels in order to control each Cameleon correctly If two or more Cameleons are addressed similarly th...

Page 15: ...14 Ordercode 42671 Cameleon Flood 15 Q4 Menu Overview...

Page 16: ...s the UP DOWN buttons to choose Program 02 Press the SET button to open the menu 03 Press the UP DOWN buttons to choose between Mode Color Speed or Strobe 04 Once you have chosen Mode press the SET bu...

Page 17: ...nu 07 Press the UP DOWN buttons to choose 4 6 or 10 DMX channels 4 Master slave With this menu you can set the device as a slave 01 While in the main menu press the UP DOWN buttons to choose Slave 02...

Page 18: ...adjust the dimming of the device by choosing a dimming curve 01 While in Settings menu press the UP DOWN buttons to choose Curves Select 02 Press the SET button to open the menu 03 Press the UP DOWN...

Page 19: ...r the safety lock is active 01 While in Settings menu press the UP DOWN buttons to choose Lock 02 Press the SET button to open the menu 03 Press the UP DOWN buttons to choose the desired option 04 You...

Page 20: ...ust be set between 1 255 0 255 Gradual adjustment Red from 0 100 Channel 4 Green Dimmer intensity CH1 must be set between 1 255 0 255 Gradual adjustment Green from 0 100 Channel 5 Blue Dimmer intensit...

Page 21: ...126 132 Color 18 R000 G000 B255 W100 133 139 Color 19 R000 G000 B255 W050 140 146 Color 20 R000 G000 B255 W000 147 153 Color 21 R075 G000 B255 W000 154 160 Color 22 R160 G000 B255 W000 161 167 Color 2...

Page 22: ...ages or material fatigue The Cameleon Flood 15 Q4 requires almost no maintenance However you should keep the unit clean Otherwise the fixture s light output will be significantly reduced Disconnect th...

Page 23: ...tically or not at all to the controller Poor data quality Check data quality If much lower than 100 percent the problem may be a bad data link connection poor quality or broken cables missing terminat...