4
Operating Determinations
•
This device is not designed for permanent operation. Consistent operation breaks will ensure that the
device will serve you for a long time without defects.
•
The minimum distance between light-output and the illuminated surface must be more than 1 meter.
•
The maximum ambient temperature
t
a
= 45°C must never be exceeded.
•
The relative humidity must not exceed 50 % with an ambient temperature of 45° C.
•
If this device is operated in any other way, than the one described in this manual, the product may
suffer damages and the
warranty becomes void.
•
Any other operation may lead to dangers like short-circuit, burns, electric shock, crash, etc.
You endanger your own safety and the safety of others!
Rigging
Please follow the European and national guidelines concerning rigging, trussing and all other
safety issues.
Do not attempt the installation yourself !
Always let the installation be carried out by an authorized dealer !
Procedure:
If the Compact Studiobeam is lowered from the ceiling or high joists, professional trussing systems
have to be used.
Use a clamp to mount the Compact Studiobeam, with the mounting-bracket, to the trussing
system.
The Compact Studiobeam must never be fixed swinging freely in the room.
The installation must always be secured with a safety attachment, e.g. an appropriate safety net
or safety-cable.
When rigging, derigging or servicing the Compact Studiobeam, always make sure, that the area
below the installation place is blocked and staying in the area is forbidden.
Improper installation can cause serious damage to people and property !
Connection with the mains
Connect the device to the mains with the power-plug.
Always pay attention, that the right color cable is connected to the right place.
International
EU Cable
UK Cable
US Cable
Pin
L
BROWN
RED
YELLOW/COPPER
FASE
N
BLUE
BLACK
SILVER
NUL
YELLOW/GREEN
GREEN
GREEN
EARTH
Make sure that the device is always connected
properly
to the earth!