background image

 

 

Never let the power-cord come into contact with other cables! Handle the power-cord and all 
connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Do not open the device and do not modify the device. 

 

Never use anything to cover the ground contact. 

 

Never look directly into the light source. 

 

Never leave any cables lying around. 

 

Never use the device during thunderstorms, unplug the device immediately. 

 

Do not insert objects into air vents. 

 

Do not connect this device to a dimmerpack. 

 

Do not switch the device on and off in short intervals, as this would reduce the lamp’s life. 

 

Do not touch the device’s housing bare-handed during its operation (housing becomes very hot).  

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

Only use device indoor, avoid contact with water or other liquids. 

 

Only operate the fixture after having checked that the housing is firmly closed and all screws are 
tightly fastened. 

 

Only operate the device after having familiarized with its functions. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always replace the lamp, when it is damaged or deformed due to the heat. 

 

Always keep case closed while operating. 

 

Always allow free air space of at least 50 cm around the unit for ventilation. 

 

Always disconnect power from the mains, when device is not used, before cleaning or when 
replacing lamp! Only handle the power-cord by the plug. Never pull out the plug by tugging the 
power-cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power-cord is never crimped or damaged. Check the device and the power-
cord from time to time. 

 

Make sure that no side forces can impact on the truss system. 

 

The cable insert or the female part in the device must never be strained. There must always be 
sufficient cable to the device. Otherwise, the cable may be damaged which may lead to deadly 
electrical shocks. 

 

If device is dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do 
not switch it on immediately. The arising condensation water might damage your device. Leave 
the device switched off until it has reached room temperature. 

 

If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely 
(preferably in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. Light effect must be installed out of the reach of children. Never leave the unit 
running unattended. 

 

For replacement use fuses of same type and rating only. 

 

This device can be installed on a flat surface or onto truss systems via the mounting bracket. 

 

The user is responsible for correct positioning and operating of the Compact Studiobeam. The 
manufacturer will not accept liability for damages caused by the misuse or incorrect installation 
of this device. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 
conductor to earth. 

 

During the initial start-up some smoke or smell may arise. This is a normal process and does not 
necessarily mean that the device is defective. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 
 
 

 

 
 

 

CAUTION ! EYEDAMAGES !. 

Avoid looking directly into the light source. 

(meant especially for epileptics) !

 

 

Summary of Contents for 42498

Page 1: ...Compact Studiobeam Smart White ORDERCODE 42498 Highlite International B V Vestastraat 2 6468 EX Kerkrade The Netherlands Phone 31 45 5667700...

Page 2: ...an rely on Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to...

Page 3: ...7 Set Up and Operation 8 Control Modes 8 One Compact Studiobeam Manual Mode 8 One Compact Studiobeam Sound control 8 Multiple Compact Studiobeams DMX Control 8 Fixture Linking 9 Data Cabling 9 Control...

Page 4: ...ancy is of a higher priority place care in providing for lower operational temperatures This may include climatic environmental and the reduction of overall projection intensity Safety Instructions Ev...

Page 5: ...never crimped or damaged Check the device and the power cord from time to time Make sure that no side forces can impact on the truss system The cable insert or the female part in the device must neve...

Page 6: ...Always let the installation be carried out by an authorized dealer Procedure If the Compact Studiobeam is lowered from the ceiling or high joists professional trussing systems have to be used Use a cl...

Page 7: ...description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our ann...

Page 8: ...White Warm White and Amber in one package Excellent white balance therefore it is very suitable for broadcast TV studio theatres and events LED Quantity 7x 3 in 1 CW WW Amber 5W Multivoltage Powersupp...

Page 9: ...hru Grey This connector sends the power to the next unit Max 20A Installation Remove all packing materials from the Compact Studiobeam Check that all foam and plastic padding is removed Connect all ca...

Page 10: ...r air circulation 2 Plug the end of the electric mains power cord into a proper electric power supply socket 3 Turn on the music If device is set to Audio and you have pressed enter then the fixture w...

Page 11: ...al data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal Maximum recommended DMX data link distance 100 meters Maximum recommended number...

Page 12: ...the DMX address of the first Mini StudioBeam should be 1 4001 the DMX address of the second Mini StudioBeam should be 1 7 8 4008 the DMX address of the third Mini StudioBeam should be 8 7 15 4015 etc...

Page 13: ...D Display will turn off after 10 seconds In this condition pressing any buttons is useless To turn the LCD display back ON press and hold one of the buttons for 3 seconds The Compact Studiobeam will a...

Page 14: ...2 5 0 128 128 43 49 6 0 128 192 50 56 7 0 128 255 57 63 8 0 255 0 64 70 9 0 255 128 71 78 10 0 255 192 79 85 11 0 255 255 86 92 12 128 0 0 93 99 13 128 0 128 100 106 14 128 0 192 107 113 15 128 0 255...

Page 15: ...128 0 121 127 17 128 128 128 128 134 18 128 128 192 135 141 19 128 128 255 142 148 20 128 255 0 149 155 21 128 255 128 156 163 22 128 255 192 164 170 23 128 255 255 171 177 24 255 0 0 178 184 25 255...

Page 16: ...103 13 128 0 128 104 110 14 128 0 192 111 117 15 128 0 255 118 124 16 128 128 0 125 130 17 128 128 128 131 137 18 128 128 192 138 144 19 128 128 255 145 151 20 128 255 0 152 158 21 128 255 128 159 165...

Page 17: ...ass cleaner and a soft cloth Do not use alcohol or solvents Keep connections clean Disconnect electric power and then wipe the DMX and audio connections with a damp cloth Make sure connections are tho...

Page 18: ...0 Ohm termination plug Insert termination plug in output jack of the last fixture on the link Incorrect addressing of the fixtures Check address setting One of the fixtures is defective and disturbs d...

Page 19: ...le for broadcast TV studio theatres and events LED Quantity 7x 3 in 1 CW WW Amber 5W Multivoltage Powersupply Driver current 350mA Refreshrate 400 Hz Dimmer 0 100 Strobe 0 20Hz Beam Angle 10 degrees O...

Page 20: ......

Reviews: