At 90˚, the miter gauge should be perpendicular to the
face of the disc when it is mounted in the X-axis table
slot. If it is not, follow this procedure to recalibrate it.
Tools.Needed:
90° Square .......................................................1
Phillips Head Screwdriver .....................................1
To.calibrate.miter.gauge,.do.these.steps:
1.
DISCONNECT MACHINE FROM POWER!
2.
Ensure sanding table is set at 0°, as covered in
Setting Table Angle on Page 17.
3.
Set one edge of a 90° square against face of miter
gauge and other edge against disc face, as shown in
Figure.23
.
4.
Loosen lock knob on miter gauge and adjust face
of miter gauge so it is flush with edge of square,
tighten miter gauge lock knob, and verify setting.
5.
Loosen degree scale pointer, position pointer on 90˚,
and retighten screw.
6.
Recheck miter scale accuracy with square.
Calibrating.Miter.Gauge
Figure.23.
Squaring miter gauge to disc.
Square
Lock Knob
Pointer
Scale
Fence