AUTOTUNE 1 TROUBLESHOOTING
AUTOTUNE 2 TROUBLESHOOTING
System will not fill
• Loss of power to the system
• Check Autotune fuse
• Ensure wiring is not damaged,
pinched or corroded.
CONDITION
CAUSE
REMEDY
ON/OFF light won’t illuminate
FILL light will not stop blinking
SET light does not stop blinking
Status lights not illuminating but
system still functioning
• No power to the system
• System cannot reach maximum
operating pressure (MIN 190 PSI)
• System has not detected signifi-
cant air flow during SET process
• Console was not able to get
above the SET point
• Status light shave burnt out
• Dimmer switch turned down
• Check Autotune fuse
• Ensure wiring is not damaged,
pinched or corroded
• Check for air leaks around the
tank, compressor and shocks
• Re-calibrate the system
• Reduce weight in the ICE
• Re-calibrate the system
• Adjust dimmer switch to
maximum brightness
• Remove panel and check for
voltage at LED’s Replace if
necessary
CONDITION
CAUSE
REMEDY