22
7. Key operation flowchart
Power ON
(*9)
PV/SV display mode
Indications differ depending on the selection in the CH1, CH2 parameter group.
PV(SV) switches while
is pressed.
PV/SV display mode
Indicates the item selected during Display selection in
the Special function group.
Returns automatically if
is released.
PV/SV Switching Mode
In the PV/SV display mode, the
SV can be indicated when PV is
indicated, and vice versa.
Standby mode
(e.g.) When Control Prohibited is selected for CH1 &
CH2.
(3 sec)
Manual control mode
(MV flashes.)
(e.g.) When Manual control MV is set to 20.0% for
CH1 & CH2.
MV Indication Mode
(The 1st point from the right flashes.)
(*1)
(*8)
SV Group
CH1 Parameter
Group
CH2 Parameter
Group
CH1 Function
Group
5
(*2)
1
CH1 SV
Control Allowed/
Prohibited
Control Allowed/
Prohibited
Input type
6
(*3)
(*4)
(*4)
CH2 SV
Auto/Manual
control
Auto/Manual
control
Scaling high limit
(*5)
(*5)
Manual control MV
Manual control MV
Scaling low limit
7
(*6)
7
(*6)
AT/Auto-reset
Perform/Cancel
AT/Auto-reset
Perform/Cancel
Decimal point
place
(*7)
(*7)
Proportional band
Proportional band
PV filter time
constant
OUT2 proportional
band
Integral time
Sensor correction
(*12)
Integral time
Derivative time
Emissivity
Derivative time
ARW
Output high limit
ARW
Manual reset value
Output low limit
Manual reset value
Proportional cycle
Output ON/OFF
hysteresis
8
Proportional cycle
Alarm 1 value
OUT2 action mode
Alarm 2 value
OUT2 proportional
cycle
OUT2 high limit
8
Alarm 3 value
Alarm 1 value
Alarm 4 value
OUT2 low limit
Alarm 2 value
Alarm 3 value
Heater burnout
alarm 1 value
OUT2 ON/OFF
hysteresis
Alarm 4 value
Heater burnout
alarm 2 value
Overlap/Dead band
Heater burnout
alarm 1 value
Loop break alarm
span
Output
rate-of-change
Heater burnout
alarm 2 value
Loop break alarm
time
Output when input
abnormal
Loop break alarm
span
(*1) This group is not available for
Potentiometer input spec,
(*2) If Cascade control is selected
from the Block function (Console
software), CH1 SV will be the AT
point of the slave.
(*3) Not available for Timer spec,
or if Heating/Cooling control
output or External setting input is
selected from the Block function
(Console software).
(*4) If Control Prohibited is
selected, the unit reverts to the
PV/SV display mode by pressing
the
key.
(*5) Not available if Automatic
control is selected. Default: MV
of the Automatic control
(*6) If
key is pressed after
Manual control MV is set, the
unit reverts to the Manual control
mode.
(*7) If
key is pressed after
AT/Auto-reset Perform is
selected, the unit reverts to the
PV/SV display mode.
(*8) Not available for Timer spec
or Potentiometer input spec, or if
Heating/Cooling control output or
External setting input is selected
from the Block function (Console
software).
(*9) PV (SV) does not switch if a
CH1, CH2 difference or addition
inclusive item is selected during
Display selection in the Special
function group.
(*10) Not available for Timer spec
or Potentiometer input spec, or if
Heating/Cooling control output is
selected from the Block function
(Console software).
(*11) If External setting input is
selected from the Block function
(Console software), and if
is pressed after input type
selection, the unit reverts to the
PV/SV display mode.
(*12) Available only for infrared
thermocouple input.
(*13) Available for Difference
(addition) input & when Base
channel is DC input.
(*14) External setting scaling
high, low limit settings:
Common to External setting
input spec, Cascade control spec
and Potentiometer input spec.
Loop break alarm
time
Heat/Cool control output
Heat/Cool control output
Heat/Cool control output