FS series operation manual
6 External input / output functions
-
55
-
6-9
Setting for the RS-232C-2 communication
RS-232C-2 communication can output the weighing data only when the data is stable.
Perform the RS-232C-2 communication setting in line with the peripheral device to which the
output is transmitted.
Printer can be used with RS-232C-2 communication.
6-9-1
Communication setting
1
Select a setting menu.
Select the communication setting.
(“2-7-2 Operation of the setting menu, setting of various
functions” and “6-1 Hierarchy of the external input/output
functions”)
2
Set the operational condition.
Inputting of the
setting value
Push the [Direction] key.
Select “421.BT.”.
Input a setting value.
「
421.BT. 0
」:
Operation OFF
「
421.BT. 1
」:
Unusable
「
421.BT. 2
」:
Operation ON
3
Set the output condition.
Inputting of the
setting value
Push the [Direction] key.
Select “422.OC.”.
Input a setting value.
「
422.OC. 0
」:
「
422.OC. 2
」:
「
422.OC. 4
」:
「
422.OC. 5
」:
「
422.OC. 7
」:
Output stop
Continuous output
at stable times
Auto output
Once at stable
times
(Output stop at
unstable times)
After [Transfer] key
is pushed down,
once at stable times